[Communication Drivers] Mitsubishi Electric Corporation FX Series CPU Direct Driver

Summary

Last update: 2021/09/30

Details

Note:
Precautions for adding a new driver onto Windows Vista or later
Precautions for adding a new driver at Daylight Saving Time
TitleMitsubishi Electric Corporation FX Series CPU Direct Driver
VersionVer. 1.16.14
Applicable SoftwareThe required versions of software for this driver installer are as follows.
GP-Pro EX Ver2.10.000 or later
Pro-Server EX Ver.1.30.000 or later
 
You can check your version by”Help”function→”Version Info”.
Related Devices
  • MELSEC FX Series
Related UnitsRequired versions depend on models.
Please check "Supported Models / Version" for the required versions of GP-Pro EX.
Required driver versions for different models are listed below
ModelRequired driver version
GP3000 SeriesVer. 1.10.01 or later
LT3000 SeriesVer. 1.15.08 or later
GP4100 SeriesGP4105Ver. 1.14.07 or later
GP4106
GP4115Ver. 1.16.09 or later
GP4116
GP4100 Series
(Ethernet Multilink only)
GP4104Ver. 1.14.07 or later
GP4114Ver. 1.16.09 or later
GP4000M SeriesVer. 1.14.07 or later
GP4000 SeriesVer. 1.14.08 or later
GP4000E SeriesVer. 1.16.09 or later
SP5000 SeriesVer. 1.15.09 or later
SP5000X SeriesVer. 1.16.13 or later
GC4000 SeriesVer. 1.14.08 or later
IPC Series for WinGP Ver. 1.11.04 or later
General PCs for WinGPVer. 1.12.05 or later
Device/PLC Connection ManualFor general information regarding Device connection and documentation conventions, please refer to "Device/PLC Connection Manual".
Updated Contents

[Ver. 1.16.14] (Sep. 30, 2021)
The following issues were corrected:

  • When Gateway Mode on the GP-4G01, occasionally a response error occurs on the HMI.
 

How to install (This is a self-extracting file.)

Please confirm that the supported software is installed in your computer. Prior to installing the driver, close all your personal computer applications, including any resident programs such as virus detection program, etc.
  1. Click on the above file name to download the data to desired folder.
  2. After the download to your PC is finished, double-click on the file’s icon to start the installer program.
  3. After the installer starts, follow the instructions given on each screen.
  4. After installation, execute GP-Pro EX.
  5. Click on the Device/PLC area’s [Mitsubishi Electric Corporation] selection and select [FX Series CPU Direct].
When using the driver, be sure to refer to the Device Connection Manual PDF.
Also, for general information regarding Device connection and documentation conventions please refer to " Device/PLC Connection Manual".

Terms of use / Cautions

Please acknowledge the following terms of use before you use our download service.
Download of any file signifies your agreement to the terms of use.
Terms and conditions

Download file

document
Installer
1.05 MB (1,100,272 Byte)
document
Device/PLC Connection Manual
1.38 MB (1,448,630 Byte)

Update History:

[Ver.1.16.14] (Sep. 30, 2021)
The following issues were corrected:

  • When Gateway Mode on the GP-4G01, occasionally a response error occurs on the HMI.


[Ver.1.16.10] 
The following settings were added:

  • GP-4G01 was supported.
    * To use a GP-4G01 Ver. 4.07.000 or later of GP-Pro EX are necessary.


[Ver. 1.16.09] (Jan. 17, 2014)
The following setting was added:

  • FX3S Series is supported.


[Ver. 1.15.09] 
The following issue was corrected:

  • When the communication type settings for GP4201T and GP4301TM are different from those of the connected devices and further the time synchronization setting is specified, the screen may be locked during the startup.


[Ver. 1.15.08] 
The following setting was added:

  • LT3000 Series is supported.


[Ver. 1.14.08] 
The following setting was added:

  • GP4000 Series is supported.
    *GP-Pro EX Ver. 3.00.000 or later is necessary to use a GP4000 Series.
The following issue was corrected:
  • When "19200" is specified for Communication Speed in GP4100 series:
  • Using the clock update function at the Display Unit's startup causes the communication error.


[Ver. 1.14.07] 
The following settings were added:

  • GP4100 Series is supported.
    *GP-Pro EX Ver. 2.60.000 or later is necessary to use a GP4106 or GP4107
    *GP-Pro EX Ver. 2.70.000 or later is necessary to use a GP4104 (Ethernet Multilink).
  • GP4000M Series is supported.
    *To use GP4000M Series, GP-Pro EX Ver. 2.71.000 or later is required.


[Ver. 1.13.07] (Dec. 28, 2008)
The following setting was added:

  • FX3G Series is supported.


[Ver. 1.12.07] (Jun. 18, 2008)
The following issues were corrected:

  • When use Device Monitor, The address length error cannot be detected. The display doesn't change into "*".
  • When GP was powered ON. The SIO error is mis-detected.
  • When Flow Control is "NONE" GP cannot be communicated.
  • When PLC is reactivated while GP is communicating. GP cannot be communicated.
  • When connecting with FX1S, FX0N, FX0S and GP starts, the address length error is mis-detected.

[Ver. 1.12.06] (Nov. 5, 2007)
The following issue was corrected:
  • When connecting with FX3U, FX3UC and GP starts, the address length error is mis-detected.


[Ver. 1.12.05] (May. 31, 2007)
The following issues were corrected:

  • When communication is not established, an error is not displayed.
  • GP cannot communicate with FX1CPU.

The following setting was added:

  • Pass-through is supported.


[Ver. 1.11.04] (Jan. 9, 2007)
The following setting was added:

  • Support for Device Monitor
    *Ver. 2.00.000 or later version of GP-Pro EX are necessary to use a DeviceMonitor.