[Communication Driver] KEYENCE Corporation KV-700 / 1000 / 3000 / 5000 CPU Direct Driver

Summary

Last update: Nov. 27, 2015

Related Devices

  • KV-700 Series
  • KV-1000 Series
  • KV-3000 Series
  • KV-5000 Series
  • KV-5500 Series
  • KV-7000 Series
  • KV-Nano Series

Related Units

ModelRequired driver version
GP3000 SeriesVer. 1.10.01 or later
ST3000 SeriesVer. 1.11.01 or later
LT3000 SeriesVer. 1.15.05 or later
GP4100 Series (GP4104: Ethernet Multilink only)Ver. 1.14.03 or later
GP4100 Series (GP4105, GP4106)Ver. 1.14.02 or later
GP4100 Series (GP4107)Ver. 1.16.06 or later
GP4000M SeriesVer. 1.14.03 or later
GP4000 SeriesVer. 1.14.04 or later
LT4000M SeriesVer. 1.15.06 or later
SP5000 SeriesVer. 1.15.06 or later
IPC Series for WinGPVer. 1.11.01 or later
General PCs for WinGPVer. 1.11.01 or later

Terms of use / Cautions

Please acknowledge the following terms of use before you use our download service.
Download of any file signifies your agreement to the terms of use.
Terms and conditions

Download file

document
Download
584.44 kB (598,465 Byte)

 

Update History

[Ver. 1.16.06] (Nov. 27, 2015)

The following functionalities were added.
  • KV-7000 Series Support
  • KV-Nano Series Support
 

[Ver. 1.15.06] (Jul. 27, 2012)

The following functionalities were added.
  • LT3000 Support
  • USB-Serial (RS-422/485) Conversion Adapter Support
 

[Ver. 1.14.06] (Feb. 17, 2012)

The following issues were corrected:
  • If "38400" or more is specified in the pass-through function, communication may not be made normally.
  • When the pass-through function is used via Ethernet, connection to PLC cannot be made.
 

[Ver. 1.14.05]

The following issue was corrected:
  • A device comment cannot be transferred via the pass-through function.
 

[Ver. 1.14.04]

The following setting was added:
  • GP4000 Series were supported.
    * GP-Pro EX Ver. 3.00.000 or later is necessary to use GP4000 Series.
The following issue was corrected:
  • When the program development tool is left online for long hours in the use of pass-through function, the communication error may occur.
 

[Ver. 1.14.03]

The following settings were added:
  • GP4000M Series were supported.
    * GP-Pro EX Ver. 2.71.000 or later is necessary to use GP4000M Series.

  • GP-4104 was supported.
    * GP-Pro EX Ver. 2.70.000 or later is necessary to use GP-4104 (Ethernet Multilink).
The following issue was corrected:
  • Reading 126 or more inconsecutive addresses of ZF device may cause a communication error.
 

[Ver. 1.14.02]

The following setting was added:
  • GP-4105 and GP-4106 were supported.
    * GP-Pro EX Ver. 2.60.000 or later is necessary to use GP-4105 or GP-4106.
 

[Ver. 1.13.02] (Oct. 16, 2008)

The following setting was added:
  • Support for Pass-through.
 

[Ver. 1.12.02] (Aug. 21, 2008)

The following issue was corrected:
  • When the KV-700/1000 series is selected, the address of an Input Relay / Output Relay / Internal Auxiliary Relay cannot be correctly set.
 

[Ver. 1.12.01] (Mar. 17, 2008)

The following settings were added:
  • KV-3000Series/KV-5000 Series are supported.
  • The driver name is changed to "KV-700/1000/3000/5000 CPU Direct".
 

[Ver. 1.11.01] (Oct. 31, 2007)

The The following setting was added:
  • Support for Device Monitor
    * GP-Pro EX Ver. 2.00.000 or later is necessary to use a Device Monitor.