PFXST6200WAD

Standard product information
Family
HMI
Series
ST6000 Series
Size
4" Wide
Model
PFXST6200WAD
Global Code
PFXST6200WAD
Product Features
4" DC Analog
Display specifications
Display type
TFT Color LCD
Display size
4.3" Wide
Resolution
480 x 272 pixels
Effective display area
W95.04 x H53.86 mm [W3.74 x H2.12 in]
Display colors
16 million colors
Backlight
White LED (Not user replaceable. When replacement is required, contact your local distributor.)
Backlight service life
50,000 hrs. or more (each in continuous operation at 25 °C [77 °F] before backlight brightness decreases to 25%)
Brightness control
16 Levels (Adjusted with touch panel or software)
Touch panel type
Resistive Film (analog, single-touch)
Touch panel resolution
1,024 x 1,024
Touch panel lifetime
1,000,000 times or more
Electrical specifications
Rated input voltage
24 Vdc
Input voltage limits
19.2 to 28.8 Vdc
Allowable voltage drop
2 ms or less
Power consumption
Max. 6.9 W
When power is not supplied to external devices: 3.6 W or less
When screen turns off the backlight (standby mode): 2.8 W or less
In-rush current
30 A or less
Voltage endurance
1,000 Vac, 20 mA for 1 minute (between power terminal and FG terminals)
Insulation resistance
500 Vdc, 10 MΩ or more (between power terminal and FG terminals)
Environmental specifications
International safety standards
CEUKCAUL,cUL (508) ListedEACKCC-Tick
Surrounding air temperature
0 to 50 °C [32 to 122 °F]
Storage temperature
-20 to +60 °C [-4 to 140 °F]
Ambient humidity
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. - no condensation)
Storage humidity
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. - no condensation)
Dust
0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)
Pollution degree
For use in Pollution Degree 2 environment
Corrosive gases
Free of corrosive gases
Air pressure (altitude range)
800 to 1,114 hPa (2,000 m [6,561 ft.] above sea level or less)
Vibration resistance
IEC/EN 61131-2 compliant
5 to 9 Hz single amplitude 3.5 mm [0.14 in.]
9 to 150 Hz fixed acceleration: 9.8 m/s2
X, Y, Z directions for 10 cycles (approx. 100 min.)
Concussion resistance
IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times
Electrical fast transient/burst
IEC 61000-4-4
2 kV: Power port (display unit)
1 kV: Signal ports
Electrostatic discharge immunity
Contact Discharge Method: 6 kV
Air Discharge Method: 8 kV
(IEC/EN61000-4-2 Level 3)
Memory
Application memory
When using BLUE:FLASH EPROM 128MB

Removable System: No
Local storage
63MB
Backup memory
When using BLUE:NVRAM 500KB

Battery: Replaceable battery / Primary battery for clock data backup
Interface specifications
Serial (COM1)
Asynchronous Transmission: RS-232C / 422 / 485, Data Length: 7 or 8 bits, Stop Bit: 1 or 2 bits, Parity: None, Even or Odd, Data Transmission Speed: 2,400 to 115,200 bps, Connector: D-Sub 9 pin (plug)
USB (Type A)
Conforms to USB 2.0 (Type A) x 1
Power supply voltage: 5 Vdc ±5 %
Output Current: 500 mA or less
Communication distance: 5 m [16.4 ft.] or less
USB (micro-B)
USB 2.0 (micro-B) x 1, Communication Distance: 5 m [16.4 ft]
Ethernet
IEEE802.3i / IEEE802.3u, 10BASE-T / 100BASE-TX, Connector: Modular jack (RJ-45) x 1
Structural specifications
Grounding
Functional grounding: Grounding resistance of 100 Ω, 2mm2 (AWG 14) or thicker wire, or your country's applicable standard. (Same for FG and SG terminals)
Cooling method
Natural air circulation
Structure
IP65F, Type 1, Type 4X (indoor use only), Type 13 (on the front panel when properly installed in an enclosure)*1
External dimensions
W134.5 x H108.5 x D43 mm [W5.3 x H4.27 x D1.69 in.]
Panel cut-out dimensions
W118.5 x H92.5 mm [W4.67 x H3.64 in.]
Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.]
When using spring clips:
Position 1: 1.5 to 4 mm [0.06 to 0.16 in.]
Position 2: 4 to 6 mm [0.16 to 0.24 in.]
*2
Weight
0.4 kg [0.88 lb] or less

1The front face of the unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the unit's level of resistance is equivalent to these standards, oils that should have no effect on the unit can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the unit's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the unit and separate protection measures are suggested. Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the unit, be sure to confirm the type of conditions that will be present in the unit's operating environment. If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.

2For dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if the installation wall thickness is within the recommended range for the "Panel Cut Dimensions", depending on wall's material, size, and installation location of GP unit and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.

Dimensions
External dimensions
Panel cut-out dimensions
A B C
118.5 mm (+1/0 mm)
(4.67 in. [+0.04/0 in.])
92.5 mm (+1/0 mm)
(3.64 in. [+0.04/0 in.])
1.6 to 5 mm
(0.06 to 0.2 in.)

When installing ST-6200WA
with spring clips:
Position 1: 1.5 to 4 mm
(0.06 to 0.16 in.)
Position 2: 4 to 6 mm
(0.16 to 0.24 in.)
External Dimensions with Spring Clips
External dimensions with cable