Communication Driver
* The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual".
Select your PLC (In alphabetical order)
- CoDeSys Automation Alliance
- Beckhoff Automation GmbH
- Control Techniques
- Control Technology Corporation
- Crouzet Automatismes SAS
- Delta-TAU data system, inc.
- Emerson Process Management
- FANUC LTD.
- Fatek Automation Corporation
- Fuji Electric Co.,Ltd.
- GE Intelligent Platforms
- Hitachi Industrial Equipment Systems Co., Ltd.
- Hitachi, Ltd.
- IEC Standard
- JTEKT Corporation
- KEYENCE Corporation
- KOYO ELECTRONICS INDUSTRIES CO., LTD.
- LS ELECTRIC Co., Ltd.
- MEIDENSHA Corporation
- Mitsubishi Electric Corporation
- Mitsubishi Heavy Industries, Ltd.
- OMRON Corporation
- Panasonic Industrial Devices SUNX Co., Ltd.
- Rockwell Automation, Inc.
- Saia-Burgess Controls Ltd.
- Schneider Electric SA
- Sharp Manufacturing Systems Corporation
- Shenzhen Inovance technology
- SICK AG
- Siemens AG
- Siemens Building Technologies
- TOSHIBA Corporation
- Shibaura Machine CO., LTD.
- YASKAWA Electric Corporation
- Yokogawa Electric Corporation
Each model of Multi-Converter (Multi-Data Box) supports the same PLC units as SP5000 Series, GP4000M Series and LT4000M Series.
LT4000M Series doesn't support RS422/485 4-wire connection.
For the ET6000 Series, please contact your local Pro-face Offie to confirm availability and support in your Country.
CoDeSys Automation Alliance
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
CoDeSys V3 Ethernet Driver (3S-Smart Software Solutions GmbH CODESYS Control Win V3, Hitachi Industrial Equipment Systems Co., Ltd. EHV+, Lenze Vertrieb GmbH Controller 3200C, Schneider Electric SA Modicon M241, Modicon M251, Modicon M262) | - | - | - | - | - | - | ||||||||
CoDeSys Ethernet (BOSCH Rexroth, WAGO, ELAU, 3S SoftPLC, KEB, Bachmann MX200 Series) | - | - | - | |||||||||||
CoDeSys SIO (BOSCH Rexroth, 3S SoftPLC) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Beckhoff Automation GmbH
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
TwinCAT ADS/AMS (Bus Terminal Controller, Embedded PC, IPC/TwinCAT2-SoftPLC, IPC/TwinCAT3-Runtime) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Control Techniques
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
MODBUS SIO Master (MODBUS Slave Device, Unidrive SP) | - | - | ||||||||||||
MODBUS TCP Master (MODBUS Slave Device, Unidrive SP) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Control Technology Corporation
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
CTC Binary Protocol (2700 Series) | - | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Crouzet Automatismes SAS
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
Millenium 3 FBD (Millenium 3 Smart, Millenium 3 Essential) | - | - | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Delta-TAU data system, inc.
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
PMAC Controller SIO (PMAC, Turbo PMAC) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Emerson Process Management
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
ROC Plus Ethernet (ROC800 (809, 827), ROC100) | - | - | - | - | - | |||||||||
ROC Plus SIO (ROC300, ROC800 (809, 827), ROCPAC 306, ROCPAC 312, ROCPAC 364, FB103, FB107, FB407, FB503, FB504) | - | - | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
FANUC LTD.
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
Power Mate Series (Fanuc Power Mate Series, Fanuc Power Mate i Series, Fanuc Series) | - | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Fatek Automation Corporation
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
FB Series SIO (FBs, FBe/FBn) | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Fuji Electric Co.,Ltd.
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
MICREX-F Series SIO (MICREX-F) | - | - | - | |||||||||||
MICREX-SX Series SIO (SPH) | - | - | - | |||||||||||
MICREX-SX Series Ethernet (SPH) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
GE Intelligent Platforms
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
Series 90-30/70 SNP (Series 90-30, Series 90-70) | - | - | - | - | - | |||||||||
Series 90-30/70 SNP-X (Series 90-30, Series 90-70, VersaMax Micro) | - | - | - | |||||||||||
Series 90 Ethernet (Series 90-30, Series 90-70, PACSystems RX7i) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Hitachi Industrial Equipment Systems Co., Ltd.
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
CoDeSys V3 Ethernet Driver (EHV+) | - | - | - | - | - | - | - | - | ||||||
H Series SIO (H(Procedure 1), H(Procedure 2), EH-150(Procedure 1), EH-150(Procedure 2), MICRO-EH(Procedure 1), MICRO-EH(Procedure 2), Web controller(Procedure 1 and 2),MICRO-EHV) | - | - | ||||||||||||
H Series Ethernet (H, EH-150, MICRO-EH, Web Controller, EHV, MICRO-EHV) | - | - | ||||||||||||
General MODBUS SIO Master (MICRO-EHV) | - | - | ||||||||||||
General MODBUS TCP Master (MICRO-EHV) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Hitachi, Ltd.
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
S10 Series SIO (S10V, HIDIC-S10α, S10mini) | - | - | - | - | - | |||||||||
S10V Series Ethernet (S10V, S10VE) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
IEC Standard
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
IEC 60870-5-101 (TELVENT, Selta STCE) | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
JTEKT Corporation
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
TOYOPUC CMP-LINK SIO (TOYOPUC-PC2,TOYOPUC-PC3J,TOYOPUC-PC3JT, TOYOPUC-PC10G) | - | - | ||||||||||||
TOYOPUC CMP-LINK Ethernet (TOYOPUC-PC3,TOYOPUC-PC10G) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
KEYENCE Corporation
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
KV-700 - 8000 SIO (KV-700 Series, KV-1000 Series, KV-3000 Series, KV-5000 Series, KV-5500 Series, KV-7000 Series, KV-8000 Series, KV-Nano Series) | - | |||||||||||||
Visual KV Series CPU Direct (Visual KV Series) | - | - | - | - | - | |||||||||
KV-10_80RW/TW CPU Direct (KV Series) | - | - | - | - | ||||||||||
KV-700 - 8000 Ethernet (KV-700 Series, KV-1000 Series, KV-3000 Series, KV-5000 Series, KV-5500 Series, KV-7000 Series, KV-8000 Series, KV-Nano Series) | - | - | - | |||||||||||
KV MODE (HOST LINK) SIO (KV-700 Series, KV-1000 Series, KV-3000 Series, KV-5000 Series, KV-5500 Series, KV-7000 Series, KV-Nano Series) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
The following devices are not listed in the GP-Pro EX Connection Device Manual but have been tested for operation. Please contact your local support office if you have any questions about the detailed connection method or other issues.
Series | CPU | Link I/F | Connection method | HMI | Communication Driver | Result Date |
---|---|---|---|---|---|---|
KV-7000 | KV-7300 | KV-XL402 | RS422/485(4 wire) | GP-4601T | General MODBUS SIO Master | 19-Oct-21 |
KV-XLE02 | Ethernet | EtherNet/IP Explicit Messaging | 15-Oct-21 | |||
General Modbus TCP Master | 18-Oct-21 | |||||
KV-8000 | KV-8000 | KV-XL402 | RS422/485(4 wire) | GP-4601T | General MODBUS SIO Master | 21-Oct-21 |
KV-XLE02 | Ethernet | General Modbus TCP Master | 22-Oct-21 | |||
EtherNet/IP Explicit Messaging | 15-Oct-21 |
KOYO ELECTRONICS INDUSTRIES CO., LTD.
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
KOSTAC/DL Series CCM SIO (KOSTAC SG, KOSTAC SU, KOSTAC SZ, KOSTAC PZ3, KOSTAC SR, DL-205, DL-405, DL-305, DirectLogic 05, DirectLogic 06) | - | - | ||||||||||||
KOSTAC/DL Series MODBUS TCP (Direct Logic05, Direct Logic06, DL205, DL405, KOSTAC SU) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
LS ELECTRIC Co., Ltd.
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
GLOFA Series Cnet (GM1/2, GM3, GM4, GM6, GM7, GM7U) | - | - | ||||||||||||
Master-K Series Cnet (K1000S, K300S, K200S, K120S, K80S) | - | - | ||||||||||||
XGK Series CPU Direct (XGK) | - | - | - | |||||||||||
XGT/XGB Series Cnet (XGT, XGB) | - | - | ||||||||||||
XGT/XGB Series FENet (XGT, XGB) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
MEIDENSHA Corporation
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
UNISEQUE Series Ethernet (UNISEQUE) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Mitsubishi Electric Corporation
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
A Series CPU Direct (MELSEC AnA Series, MELSEC AnN Series, MELSEC Q Series A Mode) | - | - | - | |||||||||||
A Series Computer Link (MELSEC AnA Series, MELSEC AnN Series, MELSEC QnA Series, MELSEC Q Series) | - | - | ||||||||||||
Q Series CPU Direct (MELSEC Q Series) | - | - | - | |||||||||||
Q/QnA Serial Communication (MELSEC Q, MELSEC QnA, MELSEC iQ-R, MELSEC iQ-F, MELSEC L) | - | - | ||||||||||||
QUTE Series CPU Direct (MELSEC Q Series) | - | - | - | |||||||||||
QnA Series CPU Direct (MELSEC QnA Series) | - | - | - | |||||||||||
FX Series CPU Direct (MELSEC FX Series) | - | - | ||||||||||||
FX Series Computer Link (FX Series) | - | |||||||||||||
A Series Ethernet (MELSEC A Series) | - | - | - | |||||||||||
Q/QnA Series Ethernet (MELSEC Q Series, MELSEC iQ-R Series, MELSEC iQ-F Series) | - | - | - | |||||||||||
Q Series QnU CPU Ethernet (MELSEC-Q Series) | - | - | - | |||||||||||
FX Series Ethernet (MELSEC-FX) | - | - | - | |||||||||||
General MODBUS SIO Master (MELSEC FX) | - | - | - | - | - | - | - | |||||||
iQ-R/F Ethernet (MELSEC iQ-R, MELSEC iQ-F) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual"
The following devices are not listed in the GP-Pro EX Connection Device Manual but have been tested for operation. Please contact your local support office if you have any questions about the detailed connection method or other issues.
Series | CPU | Link I/F | Connection method | HMI | Communication Driver | Result Date |
---|---|---|---|---|---|---|
FX5S | FX5S-60MR/ES | Ethernet Port on CPU | Ethernet (TCP) | GP-4601T | General MODBUS TCP Master | Oct 24, 2024 |
FX5-232-BD | RS232C | General MODBUS SIO Master | Oct 24, 2024 | |||
FX5-232ADP | RS232C | General MODBUS SIO Master | Oct 24, 2024 | |||
FX5-485-BD | RS422/485(4wire) RS422/485(2wire) | General MODBUS SIO Master | Oct 24, 2024 | |||
FX5-485ADP | RS422/485(4wire) RS422/485(2wire) | General MODBUS SIO Master | Oct 24, 2024 | |||
iQ-R | Q08CPU | RJ71GN11-T2 | Ethernet (TCP) Ethernet (UDP) | SP-5700TP+SP-5B10 | iQ-R/F Ethernet(SLMP Client) | May 23, 2023 |
L | L02SCPU | LJ71E71-100 | Ethernet (TCP) Ethernet (UDP) | ST-6300T | Q/QnA Series Ethernet | Nov 29, 2023 |
RS232C connector on CPU | RS232C | Q/QnA Serial Communication | Nov 29, 2023 | |||
MELSEC-Q | Q172DSCPU | PERIPHERAL I/F port on CPU unit | Ethernet (TCP) Ethernet (UDP) | GP-4601T | Q/QnA Series Ethernet | October 18, 2022 |
Mitsubishi Heavy Industries, Ltd.
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
DIASYS Netmation MODBUS TCP (Netmation CPU) | - | - | - | - | ||||||||||
MHI STEP3 Ethernet (UP/V) | - | - | - | - | - | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
OMRON Corporation
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
C/CV Series HOST Link (SYSMAC C,SYSMAC α,SYSMAC CV) | - | |||||||||||||
CS/CJ Series HOST Link (CS1,CJ1,CJ2,CP1,CP1E) | ||||||||||||||
CS/CJ Series Ethernet (CS Series, CJ1 Series, CJ2 Series, CP1 Series) | - | - | ||||||||||||
CS/CJ/NJ Series EtherNet/IP (CS1 Series, CJ2 Series, NJ Series) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
The following devices are not listed in the GP-Pro EX Connection Device Manual but have been tested for operation. Please contact your local support office if you have any questions about the detailed connection method or other issues.
Series | CPU | Link I/F | Connection method | HMI | Communication Driver | Result Date |
---|---|---|---|---|---|---|
CP2E | CP2E-N□□□□-□ CP2E-N□□□□□-□ | CP1W-CIF11 | RS422/485(4 wire) | GP-4601T | General MODBUS SIO Master | October 21, 2021 |
CP2W-CIFD2 | RS-232C RS422/485(2 wire) | |||||
CP2E-S□□□□-□ CP2E-S□□□□□-□ | Built-in RS-232C port | RS-232C | GP-4601T | General MODBUS SIO Master | October 21, 2021 | |
Built-in RS-485(2 wire) port | RS-485(2 wire) | |||||
NX | NX502-1300 | Built-in EtherNet/IP (port2) | Ethernet (TCP) | ST6300TA | CS/CJ Series Ethernet | October 03, 2023 |
Built-in EtherNet/IP (port1) Built-in EtherNet/IP (port2) | Ethernet (TCP) | ST6300TA | CS/CJ/NJ Series EtherNet/IP | September 26, 2023 | ||
NX-EIP201 | Ethernet (TCP) | GP4501T | CS/CJ/NJ Seres EtherNet/IP | Jul 29, 2024 | ||
NX502-1400 NX502-1500 | Built-in EtherNet/IP (port2) | Ethernet (TCP) | ST6300TA | CS/CJ Series Ethernet | October 03, 2023 | |
Built-in EtherNet/IP (port1) Built-in EtherNet/IP (port2) | Ethernet (TCP) | ST6300TA | CS/CJ/NJ Series EtherNet/IP | September 26, 2023 |
Panasonic Industrial Devices SUNX Co., Ltd.
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
FP Series Computer Link SIO (FP, FP7) | - | |||||||||||||
MEWTOCOL-COM Ethernet (FP7, FP0H, FP2) | - | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
The following devices are not listed in the GP-Pro EX Connection Device Manual but have been tested for operation. Please contact your local support office if you have any questions about the detailed connection method or other issues.
Series | CPU | Link I/F | Connection method | HMI | Communication Driver | Result Date |
---|---|---|---|---|---|---|
FP0H | AFP0HC32EP AFP0HC32ET | Ethernet port of the control unit | Ethernet (TCP) | GP-4601T | General MODBUS TCP Master | October 28, 2021 |
AFP0HC32P AFP0HC32T AFP0HC32EP AFP0HC32ET | AFP0HCCM1 | RS422/485(2 wire) | GP-4601T | FP Series Computer Link SIO | October 27, 2021 | |
General MODBUS SIO Master | October 28, 2021 | |||||
AFP0HCCS1 AFP0HCCS2 | RS-232C | GP-4601T | FP Series Computer Link SIO | October 27, 2021 | ||
General MODBUS SIO Master | October 28, 2021 | |||||
AFP0HCCS1M1 | RS-232C RS422/485(2 wire) | GP-4601T | FP Series Computer Link SIO | October 27, 2021 | ||
General MODBUS SIO Master | October 28, 2021 | |||||
RS232C port on CPU | RS-232C | GP-4601T | FP Series Computer Link SIO | October 27, 2021 | ||
General MODBUS SIO Master | October 28,2021 |
Rockwell Automation, Inc.
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
DF1 (SLC500, PLC-5, ControlLogix, MicroLogix, CompactLogix) | - | - | ||||||||||||
DH-485 (SLC500, ControlLogix, MicroLogix, CompactLogix) | - | - | - | - | ||||||||||
EtherNet/IP (SLC500, PLC-5, ControlLogix, ControlLogix Native, MicroLogix, CompactLogix, CompactLogix Native, FlexLogix, FlexLogix Native) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Saia-Burgess Controls Ltd.
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
SAIA Ether-S-Bus (PCD1, PCD2, PCD3) | - | - | - | - | ||||||||||
SAIA S-Bus SIO (PCD1, PCD2, PCD3, PCD4, PCD6) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
The following devices are not listed in the GP-Pro EX Connection Device Manual but have been tested for operation. Please contact your local support office if you have any questions about the detailed connection method or other issues.
Series | CPU | Link I/F | Connection method | HMI | Communication Driver | Result Date |
---|---|---|---|---|---|---|
PCD2 | PCD2.M5540 | PGU (Port 0) Port 3 | RS232C RS422/485(2 wire) | GP-4601T | Saia S-Bus SIO | October 29, 2021 |
PCD3 | PCD3.M3120 | Port 2 | RS422/485(2 wire) | GP-4601T | Saia S-Bus SIO | October 29, 2021 |
Schneider Electric SA
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
Uni-Telway (Nano, Micro, Premium) | - | - | - | |||||||||||
MODBUS SIO Master (Micro, Premium, Twido, Quantum, Momentum) | - | - | ||||||||||||
MODBUS Slave (MODBUS Series) | - | - | - | |||||||||||
MODBUS TCP Master (Premium, Quantum) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Sharp Manufacturing Systems Corporation
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
JW Series Computer Link SIO (JW10, JW20H, JW30H, JW50H, JW70H, JW100H, JW300) | - | - | - | - | ||||||||||
JW Series Computer Link Ethernet (JW30H, JW300) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Shenzhen Inovance technology
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
HMI Monitor Protocol (H1U-XP Series, H2U-XP Series, H3U-XP Series) | - | - | - | - | - | |||||||||
Modbus RTU Mode (H1U-XP Series, H2U-XP Series, H3U-XP Series) | - | - | - | - | - | |||||||||
Modbus TCP (H3U-XP Series, H5U Series) | - | - | - | - | - |
SICK AG
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
Flexi Soft (Flexi Soft) | - | - | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Siemens AG
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
SIMATIC S7 MPI Direct (SIMATIC S7-200 Series, SIMATIC S7-300 Series, SIMATIC S7-400 Series, SIMATIC S7-1200 Series) | - | - | - | - | - | |||||||||
SIMATIC S7 3964(R)/RK512 (SIMATIC S7-300 Series, SIMATIC S7-400 Series) | - | - | ||||||||||||
SIMATIC S5 CPU Direct (Series 90U-115U, Series 135U/155U) | - | - | - | - | ||||||||||
SIMATIC S5 3964(R) (SIMATIC S5 Series) | - | - | - | |||||||||||
SIMATIC S7 Ethernet (SIMATIC S7-200 Series, SIMATIC S7-300 Series, SIMATIC S7-400 Series, SIMATIC S7-1200 Series, SIMATIC S7-1500 Series, LOGO! Series) Tags can be imported. | - | - | - | |||||||||||
Ethernet Gateway for SIMATIC MPI/PROFIBUS (SIMATIC S7-200 Series, SIMATIC S7-300 Series, SIMATIC S7-400 Series) | - | - | - | |||||||||||
TIA Portal Ethernet (SIMATIC S7-1500 Series, SIMATIC S7-1200 Series) | - | - | - | - | - | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Siemens Building Technologies
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
SAPHIR SIO (SAPHIR) | - | - | - | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
TOSHIBA Corporation
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
Computer Link SIO (T Series, V Series, EX Series) | - | - | - | |||||||||||
Computer Link Ethernet (T Series, V Series) | - | - | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
Shibaura Machine CO., LTD.
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
TC Series (TC mini/TC200) (TC200, TC200S, TCmini) | - | |||||||||||||
TC/TS Series Ethernet (Tcmini, TC200) | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
YASKAWA Electric Corporation
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
- | - | |||||||||||||
- | - | |||||||||||||
- | - | |||||||||||||
- | - |
- For further information, refer to GP-Pro EX Device/PLC Connection Manual".
Yokogawa Electric Corporation
ET | ST/STM/STC | SP | GP | LT | IPC | Device Monitor *6 | Pass Through | Serial Multilink | USB/SIO RS422/485 *6 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | 6000 | 6000 | 5000 | 4000 | 4000M | 4100 | 3000 | 4000M | 3000 | PS6000 PS5000 PS4000 PE4000B PL3000 PS3000 (WinGP) | ||||
Personal Computer Link SIO (FA-M3, FCN, FCJ) | ||||||||||||||
- | - |
- For further information, refer to "GP-Pro EX Device/PLC Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
*1 Only GP-4104 can be used as a slave unit of Ethernet Multilink.
*2 The Logic Time and the Scan Time are longer in the case of the SIO connection for approximately 30%. Use the SIO connection after checking the logic executing time.
*3 When a logic executing time is long, the time to reply takes long. When time-out occurs to a Device/PLC of a master, make the time-out settings longer.
*4 Valiable is not supported
*5 Only for Power Box
*6 For the supported models, refer to "1.5 Supported Features in the Reference Manual".
*7 Only GP4100 Series color model is supported.
*8 To be supported in 2021