GP-Pro EX Connectable Devices Temperature and Process Controllers

 

Each model of Multi-Converter (Multi-Data Box) supports the same PLC units as SP5000 Series, GP4000M Series and LT4000M Series.

For the ET6000 Series, please contact your local Pro-face Offie to confirm availability and support in your Country.

 

Maker
Name
 ETST/
STM/
STC
SPGPLTIPCDevice Monitor *1Pass
Through
Serial
Multilink
USB
/SIO
RS422
/485 *1

Communication
Driver
* The lower line in
brackets shows
connected
series/device
names. For detailed
model numbers,
make sure to
refer to "Device/PLC
Connection Manual".

60006000500040004000M410030004000M3000

PS6000
PS5000
PS4000
PE4000B
PL3000
PS3000
(WinGP)

CHINO CorporationTemperature Controllers MODBUS SIO
(DB, KP, LT, JU, JW)
⇒Sample
---
Fuji Electric Co., Ltd.Temperature Controller MODBUS SIO
(PXH, PXG, PXR (AutoFIX), PXR (NoAutoFIX), PUM)
---
OMRON CorporationTemp. Controller CompoWay/F
(THERMAC NEO, THERMAC, In-Panel NEO, THERMAC)
⇒Sample
--
RKC INSTRUMENT INC.Temperature Controller MODBUS SIO
(CB, FB400/FB900, HA400/HA900, MA900, MA901, SRV, SRX, SA100, SA200, SR Mini HG (H-PCP-A), SR Mini HG (H-PCP-J), SRZ (Z-TIO), SRZ (Z-DIO), SRZ (Z-CT), SRZ (Z-COM))
⇒Sample
*2--
Temperature Controller
(CB, FB, HA, MA900, SRV, SRX, SA100, SA200, SR Mini HG (H-PCP-A/B), SR Mini HG (H-PCP-J), REX-F9000, REX-F, REX-D, REX-G9, REX-P300, REX-P250, REX-AD, REX-PG, AE500, LE100, SRZ (Z-TIO), SRZ (Z-DIO), SRZ (Z-CT), SRZ (Z-COM))
⇒Sample
*2--
Shinko Technos Co., Ltd.Indicating Controller SIO
(C, FC, FIR, GC, JC, AC, NC, DC, FCL, PC-900, ACD-13A, ACR-13A, BC▢2, PCA1, PCB1)
---
Azbil Corporation (formerly Yamatake Corporation)Controller (CPL)
(SDC10, SDC15, SDC20/21, SDC25/26, SDC30/31, SDC35/36, SDC40A, SDC40B, SDC40G, SDC45/46, DMC10, DMC50, DCP31, DCP32, DCP551, DCP552, CMC10B, C1M)
⇒Sample
--
MODBUS SIO Master
(NX, K1G, C1M)
⇒Sample
*2--
MODBUS TCP Master
(NX)
⇒Sample
---
Yokogawa Electric CorporationPersonal Computer Link SIO
(Temperature Controllers UT100 Series, Digital Indicating Controllers, UT2000)
*2

- For further information, refer to "Device/PLC Connection Manual" after clicking each manufacturer's name.
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
 

*1 For the supported models, refer to "1.5 Supported Features in the Reference Manual".

*2 To be supported in 2021

 

The following devices are not listed in the GP-Pro EX Connection Device Manual but have been tested for operation. Please contact your local support office if you have any questions about the detailed connection method or other issues.

ManufacturerSeriesCPULink I/FConnection methodHMICommunication DriverResult Date
Azbil CorporationC1MC1MT□□□A03□□Terminal block on controllerRS422/RS485 (2wire)GP-4401TController(CPL) & MODBUS SIO MasterSep. 2, 2022
Module Type ControllerAHC2001RS-232C connector on CPU unitRS232CST-6300TController(CPL) Jan. 12, 2024
Shinko Technos Co.,Ltd. AC□-13A ACD13A-□/M□,□□□
ACR13A-□/M□,□□□
Terminal of back paneRS422/485 (2 wire) GP-4501TGeneral MODBUS SIO Master Mar. 1, 2023
Indicating Controller SIO
BC□2 BCS2R00-06 Terminal of back paneRS422/485 (2 wire) GP-4501TGeneral MODBUS SIO Master Mar. 1, 2023
Indicating Controller SIO
BCD2R-06
BCR2R-06 
Terminal of back paneGP-4501TGeneral MODBUS SIO Master Dec. 19, 2022
Indicating Controller SIO
PCA1 PCA1R00-200 Terminal of back paneRS422/485 (2 wire) GP-4501TGeneral MODBUS SIO Master Mar. 1, 2023
Indicating Controller SIO
PCB1 PCB1R00-06 Terminal of back paneRS422/485 (2 wire) GP-4501TGeneral MODBUS SIO Master Dec. 19, 2022
Indicating Controller SIO
QMC1QMC1-C50-0RJ45 portRS422/485 (2 wire) GP-4501TGeneral MODBUS SIO Master Mar. 1, 2023
QTC1-4QTC1-40T-RRRRMMMM-00QTC1-4PT-RRRRMMMM-00
QMC1-C50-0
RS422/485 (2 wire) GP-4501TGeneral MODBUS SIO Master Mar. 1, 2023
QTC1-4PT-RRRRMMMM-00Terminal of back pane