{"support":{"yesButton":"Yes","noButton":"No","feedback":{"title":"What can we do to improve?"},"submitButton":"Submit","successMessage":"Thank you for your feedback","title":"Did this answer your question?","feedbackPercentLabel":"of people found this helpful","captcha":{"error":"Please check the box"}}}
Search FAQs

Pro-face LT4000M Series - Downgrade limitation of GP-Pro EX with new hardware revision

The NAND memory for Pro-face LT4000M Series listed below will be changed due to component EOL (end of life). The new NAND models will be manufactured from September 2023 onwards.

With this NAND change, Product Version (PV) and Software Version (SV) will be changed as below.
Commercial ReferenceShort DescriptionCurrent
Hardware
New NAND
Hardware
PFXLM4201TADAC3.5 Controller PanelPV: 08
SV: 8.0
PV: 09
SV: 9.0
PFXLM4201TADAK
PFXLM4201TADDC
PFXLM4201TADDK
PFXLM4301TADAC5.7 Controller PanelPV: 07
SV: 8.0
PV: 08
SV: 9.0
PFXLM4301TADAK
PFXLM4301TADDC
PFXLM4301TADDK
PFXLM4B01DACController Box for LT4000MPV: 07
SV: 8.0
PV: 08
SV: 9.0
PFXLM4B01DAK
PFXLM4B01DDC
PFXLM4B01DDK

Software Compatibility Information:
If a first project transfer is done with GP-Pro EX Ver.4.09.450 or later, downgrade version with GP-Pro EX is not possible because the OS is updated for Cybersecurity.
Please check your GP-Pro EX version before transferring the project to LT4000M.
Place of OriginGP-Pro EX
Earlier than Ver.4.03.100
GP-Pro EX
Ver.4.03.100 to Ver.4.09.400
GP-Pro EX
Ver.4.09.450 or later
GP-Pro EX
Ver.4.09.450 --> Ver.4.09.400 or earlier
LT4000M
Current Hardware
(Earlier than PV06)
Indonesia / ChinaOKOKOKOK
LT4000M
Current Hardware
(PV06 or later)
IndonesiaOKOKOKOK
ChinaNG
(Product will not start up after transfer)*
OKOKOK
LT4000M
New NAND Hardware
3.5": PV09 or later
5.7" & Box: PV08 or later
Indonesia / ChinaOKOKOKNG (Cannot transfer project file)
After upgrading to Ver.4.09.450, there's no way to downgrade to Ver.4.09.400 or earlier.
*In case you are using LT4000M Current Hardware (PV06 or later) made in China, GP-Pro EX Ver.4.03.100 or later is required.

Where to find PV and SV information:
You can find the information on Product Label on the back side of the main unit.
PV = Product Version
SV = Software Version