{"support":{"yesButton":"Yes","noButton":"No","feedback":{"title":"What can we do to improve?"},"submitButton":"Submit","successMessage":"Thank you for your feedback","title":"Did this answer your question?","feedbackPercentLabel":"of people found this helpful","captcha":{"error":"Please check the box"}}}
Pro-face LT4000M Series - Downgrade limitation of GP-Pro EX with new hardware revision
The NAND memory for Pro-face LT4000M Series listed below will be changed due to component EOL (end of life). The new NAND models will be manufactured from September 2023 onwards.
With this NAND change, Product Version (PV) and Software Version (SV) will be changed as below.
Software Compatibility Information:
If a first project transfer is done with GP-Pro EX Ver.4.09.450 or later, downgrade version with GP-Pro EX is not possible because the OS is updated for Cybersecurity.
Please check your GP-Pro EX version before transferring the project to LT4000M.
Where to find PV and SV information:
You can find the information on Product Label on the back side of the main unit.
PV = Product Version
SV = Software Version
With this NAND change, Product Version (PV) and Software Version (SV) will be changed as below.
Commercial Reference | Short Description | Current Hardware | New NAND Hardware |
PFXLM4201TADAC | 3.5 Controller Panel | PV: 08 SV: 8.0 | PV: 09 SV: 9.0 |
PFXLM4201TADAK | |||
PFXLM4201TADDC | |||
PFXLM4201TADDK | |||
PFXLM4301TADAC | 5.7 Controller Panel | PV: 07 SV: 8.0 | PV: 08 SV: 9.0 |
PFXLM4301TADAK | |||
PFXLM4301TADDC | |||
PFXLM4301TADDK | |||
PFXLM4B01DAC | Controller Box for LT4000M | PV: 07 SV: 8.0 | PV: 08 SV: 9.0 |
PFXLM4B01DAK | |||
PFXLM4B01DDC | |||
PFXLM4B01DDK |
Software Compatibility Information:
If a first project transfer is done with GP-Pro EX Ver.4.09.450 or later, downgrade version with GP-Pro EX is not possible because the OS is updated for Cybersecurity.
Please check your GP-Pro EX version before transferring the project to LT4000M.
Place of Origin | GP-Pro EX Earlier than Ver.4.03.100 | GP-Pro EX Ver.4.03.100 to Ver.4.09.400 | GP-Pro EX Ver.4.09.450 or later | GP-Pro EX Ver.4.09.450 --> Ver.4.09.400 or earlier | |
LT4000M Current Hardware (Earlier than PV06) | Indonesia / China | OK | OK | OK | OK |
LT4000M Current Hardware (PV06 or later) | Indonesia | OK | OK | OK | OK |
China | NG (Product will not start up after transfer)* | OK | OK | OK | |
LT4000M New NAND Hardware 3.5": PV09 or later 5.7" & Box: PV08 or later | Indonesia / China | OK | OK | OK | NG (Cannot transfer project file) After upgrading to Ver.4.09.450, there's no way to downgrade to Ver.4.09.400 or earlier. |
*In case you are using LT4000M Current Hardware (PV06 or later) made in China, GP-Pro EX Ver.4.03.100 or later is required. |
Where to find PV and SV information:
You can find the information on Product Label on the back side of the main unit.
PV = Product Version