***************************** GP-Pro EX Ver.4.0 **************************** Dec 2016 Digital Electronics Corporation Preface Thank you for using GP-Pro EX. GP-Pro EX is software to create logic programs and screen data for graphical operation touch panels. The Windows environment ensures operability and high performance. Please visit the Pro-face website (http://www.pro-face.com/) for the latest information. Table of Contents (0) Version (1) New Features List = V4.06.100 ===== 1-1 Support of New Features = V4.06.000 ===== 1-1 Support of New Features = V4.05.100 ===== 1-1 Support of New Features = V4.05.000 ===== 1-1 Support of New Features = V4.04.000 ===== 1-1 Support of New Features = V4.03.300 ===== 1-1 Support of New Features = V4.03.100 ===== 1-1 Support of New Features = V4.03.000 ===== 1-1 Support of New Features = V4.02.000 ===== 1-1 Support of New Features = V4.01.000 ===== 1-1 Support of New Features = V4.00.000 ===== 1-1 Support of New Features (2) Limitations 2-1 Editor 2-2 Display Unit 2-3 Device/PLC 2-4 WinGP 2-5 Pro-face Remote HMI Server (3) When Serial No. and License Key Code are not input (4) Installation and Uninstallation 4-1 Installation 4-2 Uninstallation (5) User Registration (6) Manuals (7) Fixed Defects = V4.06.200 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.06.101 ===== 7-1 Installation = V4.06.100 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.05.100 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC 7-4 Pro-face Remote HMI Server = V4.05.000 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.04.100 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC 7-4 Pro-face Remote HMI Server = V4.04.000 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.03.400 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.03.300 ===== 7-1 Display Unit = V4.03.200 ===== 7-1 Editor 7-2 Display Unit = V4.03.100 ===== 7-1 Editor 7-2 Display Unit 7-3 Pro-face Remote HMI Server = V4.03.000 ===== 7-1 Editor 7-2 Display Unit 7-3 Pro-face Remote HMI Server = V4.02.000 ===== 7-1 Editor 7-2 Display Unit 7-3 Pro-face Remote HMI Server = V4.01.000 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC = V4.00.000 ===== 7-1 Editor 7-2 Display Unit 7-3 Device/PLC Contents ================================================================================ (0) Version Editor: Ver.4.06.200 System/Runtime: Ver.4.6.20 Sub-system/OS Core: Ver.4.6.20 (GP4000 series except for GP4000M series, GP-4104, GP-4105, GP-4106, and GP-4107.) Ver.4.6.10 (SP-5B10) Ver.1.2.7 (LT4000 series) Ver.1.3.3 (GP4000M series) Ver.1.1.3 (GP-4104) Ver.1.3.5 (GP-4105, GP-4106, GP-4107) Ver.3.6.5 (GP3400 series, GP3500 series, GP3600 series, GP3700 series) Ver.3.6.0 (ST3000 series, GP-3200 series, AGP3310HT, AGP3300HS/HL) Ver.3.6.3 (LT-3300 series, AGP3300T/U/S/L, AGP3301S/L) Ver.3.5.1 (Other than above models) Memory Loader: Ver.4.6.20 (1) New Features List = V4.06.100 =================================================================== 1-1 Support of New Features - SP5000 Series Open Box (SP5B40) now supports the following display modules: - SP-5600TP SVGA (800*600) - SP-5660TP SVGA (800*600) - SP-5700TP SVGA (800*600) - SP5000 Series Power Box (SP-5B10) now supports display modules with 9-point calibration settings. - The [Do not transfer all if no change in project] option is now available in the [Save as] dialog box. - You can now use system variables to check the recipe label of enhanced recipes. - You can now edit a display unit's [Ethernet] settings from the Transfer Tool. - You can now use system variables to check the project file name. = V4.06.000 =================================================================== 1-1 Support of New Features - GP-4311HT is now supported. = V4.05.100 =================================================================== 1-1 Support of New Features - On the Open Box, you can now use WinGP to check the status of the operating system's Enhanced Writer Filter (EWF). = V4.05.000 =================================================================== 1-1 Support of New Features - The following 3 models are now supported. - GP-4114T - GP-4115T - GP-4116T - You can now use the device/PLC to change screens on Remote HMI (client) set to asynchronous mode. - Function version upgraded communication driver - Mitsubishi Electric Corporation iQ-R/F Ethernet - Pass-Through function supported. - YASKAWA Electric Corporation MP Ethernet/MECHATROLINK Driver - The driver name changed from "MP/INVERTER/SERVO Ethernet" to "MP Ethernet/MECHATROLINK". - R7G4HML3-LC2 of M-System Co., Ltd now supported. - K1G of Azbil Corporation now supported. - Cognex Corporation In-Sight Vision Systems - In-Sight 7000 now supported. - KEYENCE Corporation KV-700/1000/3000/5000 CPU Direct - KV-7000/KV-Nano Series now supported. - KEYENCE Corporation KV-700/1000/3000/5000 Ethernet - KV-7000/KV-Nano Series now supported. - PS-5000, PS/PE-4*00 series and PC/AT now support portrait orientation. - The following products now run on Windows 10. - GP-Pro EX (screen editor) - Transfer Tool - Version Reverter - Project Comparison Tool - Project Converter - Recovery Tool - Pass-Through - Device Data Copy Tool - Pro-face Remote HMI Server - GP-Viewer EX = V4.04.000 =================================================================== 1-1 Support of New Features - WinGP now supports True Colors for Image and JPEG files. - WinGP now supports high resolution for PS-5000, PS/PE-4*00 series and PC/AT. - The Project Converter now supports LT3300T. - You can now enter the GP-Viewer EX key code from the Transfer Tool. - WinGP now supports PS-5000 series. - WinGP SDK now runs on Microsoft .Net Framework 4.0. - Newly-added communication driver - Mitsubishi Electric Corporation iQ-R/F Ethernet - Panasonic Industrial Devices SUNX MEWTOCOL7-COM Ethernet - Function version upgraded communication driver - ODVA EtherNet/IP Explicit Messaging - Custom Explicit now supports "Get Attribute Single" Service (0x0e) and "Set Attribute Single" Service (0x10). - Azbil Corporation Controller (CPL) - Burner Controller BC-R series now supported. - Mitsubishi Electric Corporation Q/QnA Series Ethernet - High-Speed Universal Model (QnUDVCPU) now supported. - Mitsubishi Electric Corporation Q Series QnU CPU Ethernet - High-Speed Universal Model (QnUDVCPU) now supported. - Rockwell Automation, Inc. EtherNet/IP - When automatic port number allocation is enabled, you can now configure Individual Device Settings to one physical target PLC for both the "ControlLogix/CompactLogix Series" and "Control/Compact/Flex Logix Series Native". - JTEKT Corporation TOYOPUC CMP-LINK SIO - PC10G-CPU now supported. - PC3JG-CPU's EB device now supported. - JTEKT Corporation TOYOPUC CMP-LINK Ethernet - PC3JG-CPU's EB device now supported. - Relay communication now supported. - Azbil Corporation MODBUS SIO Master - Series name change from KG to K1G. - Beckhoff Automation GmbH TwinCAT ADS/AMS - AMS NetID setting now supported in offline mode. - Pass-Through Function Setting Tool - Timeout setting now supported. - Mitsubishi Electric Corporation iQ-R/F Ethernet - Label import function now supported (iQ-R series only). - Panasonic IndustrialDevices SUNX FP Series Computer Link SIO - Change in maker name. Panasonic Electric Works SUNX Co., Ltd. -> Panasonic Industrial Devices SUNX - Seiko Epson Corporation Remote Ethernet - A new device now supported. - Siemens AG SIMATIC S7 MPI Direct - Tag import dialog box now improved. - Siemens AG SIMATIC S7 Ethernet - Tag import dialog box now improved. = V4.03.300 =================================================================== 1-1 Support of New Features - GP4000 series (except for GP4100 series, GP-4201TM and GP-4301TM) supported compatible parts for stable service. = V4.03.100 =================================================================== 1-1 Support of New Features - You can now expand the user screen area in AGP-3560T. = V4.03.000 =================================================================== 1-1 Support of New Features - You can now check search results from a recipe list part by using system variables. - You can now use a system variable to copy, save, and reload recipes. - You can now receive recipe labels. - The File Manager can now use the Remove DEL Key feature with CF/SD cards. - Pro-face Remote HMI is now available in WinGP. - Pro-face Remote HMI now supports multiple client connections. - Function version upgraded communication driver - OMRON Corporation CS/CJ/NJ Series EtherNet/IP - Added support for double-byte characters on the NJ series. - YASKAWA Electric Corporation MP/INVERTER/SERVO Ethernet - Sigma-7 series is supported. = V4.02.000 =================================================================== 1-1 Support of New Features - In the Common Settings, you can now set up [No timeout] for the timeout time. - In the Common Settings, you can now set up [No timeout] for the timeout time. - When communication is unstable, you can now define a timer for terminating the connection. - When using the Start application command, you now have the option to suppress WinGP CPU usage. - Function version upgraded communication driver - ODVA EtherNet/IP Explicit Messaging - Implicit messaging now supported. - Custom Explicit message now supported. - TOSHIBA MACHINE Co., Ltd. TC Series(TCmini/TC200) Device Data Copy Tool - Now supports VGA display. - YASKAWA Electric Corporation MEMOBUS Ethernet Device Data Copy Tool - Added support for new transfer files. (Maintenance Monitor Setting, FTP Client definition.) - The following products now run on Windows 8.1. - GP-Pro EX (screen editor) - Transfer Tool - Version Reverter - Project Comparison Tool - Project Converter - Recovery Tool - Pass-Through - WinGP - WinGP SDK - Device Data Copy Tool - Open Box (SP5B40) models now support portrait orientation. - The following now support VGA display: - SP5000 series (Box Module) - SP-5B10 (Display Module) - SP-5500TP - SP-5600TP - SP-5660TP - SP-5700TP = V4.01.000 =================================================================== 1-1 Support of New Features - You can now import the recipe data of enhanced recipes. - Importing/exporting enhanced recipes You can now import and export element labels and recipe labels. - Enhanced recipe search You can now use system variables to search for enhanced recipes. - Mapped address You can now edit enhanced recipe element values on the device/PLC. - Send options When transferring an enhanced recipe to a device/PLC, you can write the enhanced recipe's label and ID to the defined address. - Function version upgraded communication driver - Beckhoff Automation GmbH TwinCAT ADS/AMS - Support TwinCAT3. - Reading a large number of array elements has been optimized. = V4.00.000 =================================================================== 1-1 Support of New Features - The following models are now supported: - GP-4000M (Rear Modular Type) - SP5000 series (Box Module) - SP-5B10 - SP-5B40 (Display Module) - SP-5400WA WVGA(800*480) - SP-5500WA WXGA(1280*800) - SP-5500TP SVGA(800*600) - SP-5600TP XGA(1024*768) - SP-5660TP XGA(1024*768) - SP-5600WA WXGA(1280*800) - SP-5700TP XGA(1024*768) - Pro-face Remote HMI Server function is now supported. - Pro-face Remote HMI function is now supported on the SP5000 Series. - Pro-face Remote HMI function is now supported on the GP-4000M Series. - Server list screen now supports monitoring triggered alarms. - You can now create a project using [Create Project From Configuration File (Pro-face Device Configurator)]. - Newly-added communication driver - CoDeSys Automation Alliance CoDeSys Ethernet - CoDeSys Automation Alliance CoDeSys SIO - Control Techniques MODBUS SIO Master - Control Techniques MODBUS TCP Master - IEC Standard IEC 60870-5-101 - Siemens AG Ethernet Gateway MPI/PROFIBUS - Function version upgraded communication driver - Mitsubishi Electric Corporation FX Series CPU Direct The following setting was added: FX3S Series is supported. (2) Limitations 2-1 Editor - Comparison result of [Device/PLC settings] may appear as "Different" though project files have same [Device/PLC] Settings. 2-2 Display Unit (Runtime) - When a USB device is inserted/removed, all USB devices may not become disabled under the condition that five or more USB devices are connected at the same time using the USB HUB in GP-4000 series. If this phenomenon occurs, reset the Display. - When two or more Data Displays with "Indirect" specified are made to be invisible at the same time while displaying a pop-up keypad, some Data Display may not be invisible. - A keypad is closed while the [Alt] key on the keypad of the RPA Window Display is held down. When the keypad is opened next time, the [Alt] key remains held down. - Do not use a logic program during communication with a Device/PLC using a USB/SIO (RS422/485). If the logic program is used in the situation, a communication error may occur. - In GP4000 series (except for GP-4100 series) and LT4000 series, the buzzer sound in Ver. 3.5 is different from that in Ver. lower than 3.5. - Do not attach/detach the fingerprint authentication unit while turning on the power to the Display. Doing so, inconsistency occurs between the security data and the fingerprint data and the display of the authentication and the password setting may not operate normally. If an inconsistency occurs between them due to attachment/detachment of the fingerprint authentication unit, update the fingerprint data of the fingerprint authentication unit using the "Update DB" function. - Do not attach/detach the transfer cable while transferring to the SP5000 Series Open Box (SP-5B40). Even if the cable is detached, the unit will not detect an error. - On the Power Box(SP-5B10) of the SP5000 series, In the case of forced transfer mode, you cannot transfer using LAN2. - Compared to other series, the buzzer for the Open Box's (SP-5B40) Bit Momentary switch sounds different. - The Windows task bar flickers if you continually trigger the system menu's display operation (simultaneously touch the top-right and bottom-left corners) on the SP5000 series Open Box (SP-5B40). - On models that support 2-point touch, while the first touch is initiated and you work with the system menu, system menu operations may not work. Display the system menu again and menu operations become available. - On the SP5000 series Open Box (SP-5B40), after transfer operation, restarting or closing WinGP causes the sound to buzzer and lights to flash in red for all lights on the EZ Tower Light. - On the SP5000 series Open Box (SP-5B40), even though there are no devices connected, in the offline menu, the Peripheral Settings screen's USB Screen shows USB equipment. - On the GP4200 Series, GP4300 Series, and LT4000 Series, you cannot edit Web Server settings offline. - With the SP5000 Series Power Box (SP-5B10) and WinGP, do not touch the top-right or top-left corners while starting up. While normally this would take you to offline mode, there are certain circumstances when this will not work. - When using Load Text Table with code page 850, there is the case that Text table is not displayed correctly. - On the GP-4100 Series (Color Model), if you download the different CML file in a row without ending the memory loader, SRAM may be initialized after restarting the display unit. - When the [Compress] check box is selected, transparency may not display properly. - Search results may not display if you use system variables to search for a recipe, while deleting a recipe in an Enhanced Recipe List part. When this occurs, reset the display unit. - When there are a large number of recipes, importing recipes may take considerably longer than it did in Ver.4.6.10. - When [Display Unit] - [Operation] - [Output to External Buzzer Terminal] is enabled on the GP3300H or GP4000H series, the GP3000H conversion adapter emits the external buzzer for the following operations from the maintenance menu. - Check Pattern - Check Touch Panel - Calibrate Touch Panel - Check COM1/COM2/LAN - Memory Info - Check Function Switch - When the operation switch is enabled on the GP4000H series, only monitoring is possible from the client. The client cannot perform any operations. - Occasionally the File Manager does not sort its operation log's output files in file creation order. - In the destination, if you specify a FTP server with PASV disabled, file write may fail and a 0-byte sized file may be created in the destination folder. 2-3 Device/PLC - In Pro-Server EX's Device Monitor function when a Multiple Bit Write operation is performed on an array type Tag it may not write correctly. - When single bit write operation is performed on a 32-bit Tag(DINT), the 16th bit cannot be written. - When a Copy / Paste operation which results in the maximum number of Tags being exceeded no error is displayed. - When several Tag Data Files are created, the maximum number of Tags may not be checked correctly. - In Pro-Server EX's Device Monitor function the Multiple Bit Write operation may not work in some cases. - Do not use "Indirect" setting for the String type. If it is specified, data may not be displayed normally. - When STRING variables are displayed in Device Monitor of Pro-Server EX, only two characters are displayed. - Some spelling mistakes are found in English error messages. - If an error occurs during communication, set "1" or larger value for Retry Count. - When a bit device is specified in Alarm Summary, alarms of 17th bit or later are not displayed normally. If this phenomenon occurs, use the word device. - When the link parameter device is read, the communication cycle time becomes an illegal value. - In a screen where a Display Unit does not communicate with a PLC: When an access is made to the PLC using the pass-through function after the PLC is restarted, the password lock occurs to the PLC. Make connections using the pass-through function after the screen is shifted to the one where the Display Unit communicates with the PLC. - Do not write the data including the bit address with the extended recipe function. If such writing is made, a communication error may occur. - Do not input 32 or more characters for the device address in Address Input of Device Monitor. - Tag information allocated to I/O units may not be imported normally. If this phenomenon occurs, edit the data with the Editor manually. - When bit read/write for two or more points is performed to a bit-accessible word device or word type tag, an address other than the specified address may be read/written. - The pass-through function cannot be used when WinGP and IIS FTP servers are used at the same time. 2-4 WinGP - The buzzer of WinGP does not sound in PS-4700 (Z510). - When the File Manager displays a folder path and data in that folder is updated, the folder path reverts to the default path. - The system load status or wireless communication status may prevent the application from disconnecting within the time specified by the property: Disconnect after communication is down for. 2-5 Pro-face Remote HMI Server - In Windows 8 / 8.1 / 10, application distribution fails to correctly display distributed screens of Excel 2013 on the client. To distribute Excel 2013 screens, use desktop distribution. (3) When Serial No. and License Key Code are not input - Project data cannot be transferred to the operation panels (except for GP4100 series, IPCs and PC-ATs (Used WinGP)). - Transfer using the Transfer Tool is not available for WinGP. However, using ProjectCopy, you can copy screen data and get it to work. To use ProjectCopy, click [Start]-[All Programs]-[Pro-face]-[WinGP]- [ProjectCopy] on the Windows desktop screen. However, note that ProjectCopy cannot be used in the following cases: - When system data has not been transferred - When system data has been changed WinGP automatically stops after three hours of continuous operation. * It is possible to input the serial No. and the license key code after installation of the software. Start the product and go to [Help]-[Enter Key Code]. (4) Installation and Uninstallation 4-1 Installation - Be sure to quit all application programs and close (disable) all resident programs such as virus detection software before installing the software. - Install this software using a user account with Administrator privileges. - When reinstalling or updating RemoteHMIServer, begin installation only after uninstalling the application and restarting the computer. - If you update while the Pro-face Remote HMI Server is running, installation may fail. - Refer to our support site "Otasuke Pro!" (http://www.pro-face.com/otasuke/) for the operating environment. - By inserting a disk into the DVD drive, Setup window will appear. If the Setup window does not appear, click the desktop's [Start] button and then click [Run]. In the text input field, enter [D:\ProEX_Setup.exe] and click [OK]. (As for the "D:\" part, enter your DVD drive name.) * Some of the tools require a license. In cases below, USB transfer cables may not be recognized correctly: - When you installed the software with a USB transfer cable connected - When you started using the software without restarting your computer - 1)Insert the Windows installation media. If you do not have the Windows installation media, contact the PC manufacturer. 2)Select "Open command prompt as administrator" on the Explorer. 3)Execute the following command at the Command Prompt. Dism /online /enable-feature /featurename:NetFx3 /All /Source:x:\sources \sxs /LimitAccess *) For x:, specify the drive letter of Windows installation media or the DVD drive. 4-2 Uninstallation To uninstall the software, click on [Start], then select [All Programs]- [Pro-face]-[***], and execute [Uninstall]. ("***" represents the product name and version.) Project files and files in your package files will not be removed by this operation. Delete other tools from [Start]-[Control Panel]- [Add or Remove Programs]. (5) User Registration Please register your software to help us offer enhanced customer support. Since you can confirm the registered information at anytime once you register, you do not have to worry even if you lose it. To register, insert a DVD into the DVD drive, select the User Registration menu in the Set Up Menu screen and complete the online Software User Registration. You can also register after installation by starting the product and registering from [Help]-[Online User Registration]. (6) Manuals To view PDF manuals, the Adobe Reader software must be installed on your computer. Start the product and select [Manual] from the [Help(H)] menu. To view only the manuals, select [Start]-[All Programs]-[Pro-face]-[***] -[Manual].("***" represents the product name and version.) Some manuals need to be downloaded from our support site "Otasuke Pro!". (7) Fixed Defects = V4.06.200 =================================================================== 7-1 Editor - In the Text Table Settings, when the value in the Change Language control address is out of range (17 or greater), editing the label in an extended recipe could cause simulation to exit unexpectedly. - Using unregistered variables in the function block of a logic program occasionally caused simulation to exit unexpectedly. - Occasionally simulation stopped working when you assigned a fractional value to a Float or Real data type variable. 7-2 Display Unit - Occasionally this tool was unable to copy projects associated with PS-5000 or PS/PE-4000 models to WinGP. - Occasionally, the SP500 Series Power Box (SP-5B10) did not communicate properly over the COM port. - An USB device with three or more configuration descriptors becomes unusable when connected to the GP4000 Series (except GP-4100 Series, GP-4201-TM, and GP-4301TM). - Occasionally, the SP500 Series Power Box (SP-5B10) did not communicate properly over the USB/SIO(RS232C) and USB/SIO(RS422/485) cables. - Occasionally, the SP500 Series Power Box (SP-5B10) did not accept input from a USB bar code reader properly. - When using the SP5000 Series Power Box (SP-5B10) with the Advanced Display (SP-5x00WA), occasionally touch panel operations did not work properly. - On the GP-4100 Series (color model), after using a Special Switch to transfer filing data from the device/PLC to SRAM and the display unit was turned OFF, occasionally the transferred data was not saved. - When you setup the System Data Area as a PLC device, and you save sampling data in CSV format, occasionally the timestamp for sampling data is shown as 00:00:00. - In rare cases, using drawing functions in extended scripts caused the display unit to stop working. - On the LT4000 Series, after the PLSQ instruction you could not output acceleration/deceleration pulses from the PLSY instruction only. - When you start Monitor Step on the SP5000 Series Power Box (SP-5B10), the value in a portion of the bit variables used in function blocks could not be refreshed. - Even when communication is not yet established with a PLC once, now you can still back up internal devices.