Serial
The cable/adapter requirements vary depending on other devices. Please refer to the following manual. .Product Name | Model No. | Description |
---|---|---|
RS-232C Cable (5m) | CA3-CBL232/5M-01 | Connects a host controller to the GP unit (RS-232C) |
RS-422 Cable (5m) | CA3-CBL422-01 | Connects a host controller to the GP unit (RS-422) |
Mitsubishi PLC A-Series Connection Cable (5m) | CA3-CBLA-01 | Connects Mitsubishi PLC A or QnA Series programming console I/F to GP unit (Simultaneous use of programming consoles is not possible.) |
Mitsubishi PLC Q-Series Connection Cable (5m) | CA3-CBLQ-01 | Connects Mitsubishi PLC Q-Series programming console I/F to GP unit (Simultaneous use of programming consoles is not possible.) |
Mitsubishi PLC Q-Series Link Cable (5m) | CA3-CBLLNKMQ-01 | Connects Mitsubishi PLC Q-Series (or other host controller) to the GP unit (RS-232C) |
Mitsubishi PLC FX-Series Connection Cable | CA3-CBLFX/1M-01 | Connects Mitsubishi PLC FX-Series programming console I/F and GP unit (Simultaneous use of programming consoles is not possible.) |
Mitsubishi PLC FX-Series Connection Cable | CA3-CBLFX/5M-01 | Connects Mitsubishi PLC FX-Series programming console I/F and GP unit (Simultaneous use of programming consoles is not possible.) |
Omron PLC SYSMAC Link Cable (5m) | CA3-CBLSYS-01 | Connects Omron PLC SYSMAC Series unit (or other host controller) to the GP unit (RS-232C) |
Siemens TTY Converter Cable (5m) | CA6-CBLTTY/5M-01 | Connects Siemens PLC S5 Series to the GP unit |
9-pin-to-25-pin RS-232C Conversion Cable (0.2m) | CA3-CBLCBT232-01 | Connects a standard RS-232C cable (D-Sub 25-pin socket) to the GP unit (D-sub 9 pinplug) |
2 Port Adapter Cable (5m) | CA3-MDCB11 | Connects Mitsubishi PLC to the GP unit using 2 port adapter II (RS-422) |
MPI Cable (3.5m) | ST03-A2B-MPI21-PFE | Connects a host controller to the GP unit for MPI communication |
Mitsubishi PLC A, QnA, FX series 2 port adapter II | GP070-MD11 | Allows simultaneous use of an GP unit and a Mitsubishi PLC A, QnA, FX series peripheral device |
Multi-link cable | CA3-CBLMLT-01 | Connects a host controller to GP unit for multi-link (n:1) communication |
USB
Product Name | Model No. | Description |
---|---|---|
EZ Tower Light tube mounting with fixing plate | PFXZCETWHA1 | USB Connection Type Monolithic EZ Tower Light tube mounting with fixing plate |
EZ Tower Light with base mounting | PFXZCETWW1 | USB Connection Type Monolithic EZ Tower with base mounting |
EZ Illuminated Switch | PFXZCCEUSG1 | A unit of 5 illuminated switches with multiple color LED easily connected with HMI via USB |
EZ Numpad | PFXZCCEUKB1 | A unit of ten-key pad easily connected with HMI via USB |
EZ Fingerprint Recognition Unit | PFXZCCEUSS1 | A unit of fingerprint identification easily connected with HMI via USB |
USB Front Cable (1m) | CA5-USBEXT-01 | Extension cable attaching USB interface to front panel |
USB-Serial (RS-232C) Conversion Cable (0.5m) | CA6-USB232-01 | Cable for converting a GP unit’s USB interface into a serial interface (RS-232C). Allows connection to modems or barcode readers that support RS-232C |
USB Transfer Cable (USB Type A/mini-B) (1.8m) | ZC9USCBMB1 | Cable for transferring screen data from a PC (USB Type A) to the GP unit (USB mini-B) |
USB Panel-mount Extension Cable (USB mini-B) (1m) | ZC9USEXMB1 | Extension cable that attaches to the USB (mini-B) interface on the front side of the operation panel |
USB Cable (5m) | FP-US00 | Connects a USB printer (TYPE-B) |
Software
Product Name | Model No. | Description | |
---|---|---|---|
GP-Pro EX Ver. 4.03.400 or later | PFXEXEDV*** | HMI Screen Editor & Logic Programming Software | |
GP-Pro EX Editor License | PFXEXEDLS** | GP-Pro EX editor license | |
GP-Viewer EX | 1 licence | PFXEXVW | License allowing a PC to access a GP4000E in remote mode. |
10 licence | PFXEXVWLS10 | ||
30 licence | PFXEXVWLS30 |
Others (Unit / Adapter / Sheet)
Product Name | Model No. | Description | |
---|---|---|---|
COM Port Conversion Adapter | CA3-ADPCOM-01 | Connects optional RS-422 communication items to GP unit’s Serial Interface | |
Terminal Block Conversion Adapter | CA3-ADPTRM-01 | Connects output from a serial interface with an RS-422 terminal block | |
Wide Screen Protection Sheet | 7-inch | PFXZCBDS72 | Disposable, dirt-resistant sheet for the GP unit's screen (5 sheets/set) |
UV Protection Sheet | 10-inch Wide | PFXZCFUV102 | Ultraviolet protection for the display (1 piece) |
7-inch Wide | PFXZCFUV72 |
Maintenance Options
Product Name | Model No. | Description | |
---|---|---|---|
Replacement Battery | PFXZGEBT1 | Primary battery for memory and time data backup (1 piece) | |
Wide Installation Gasket | 7-inch | PFXZCCWG7W1 | Provides dust and moisture resistance when GP is installed into a solid panel (1 piece) |
10-inch | PFXZCCWG10W1 | Provides dust and moisture resistance when GP is installed into a solid panel (1 piece) | |
DC Power Supply Connector | CA5-DCCNM-01 | Connector to connect DC power supply cables (5 pcs/set) | |
Installation Fastener | PFXZCFAF1 | Used to install the GP into a solid panel (4 pieces/ set) |