PFXP63Exxxxxxxxxxx (12" Wide, Core i3 model)

Standard product information
Family
Industrial PC (IPC)
Series
PS6000 Series
Size
12" Wide
Model
PFXP63Exxxxxxxxxxx
Global Code
PFXP63Exxxxxxxxxxx
Product Features
12" Wide, Core i3 model
Industrial PC specifications
Supported OS
Windows10 IoT Enterprise 2019 LTSC (64bit)
or
Windows10 IoT Enterprise 2021 LTSC (64bit)
CPU
Core i3-8145UE (Dual Core, 4 Threads, up to 3.90 GHz)
L2 cache memory
4MB
Main Memory
260-pin SO-DIMM socket x 2, DDR4-2400
(Up to 16 GB/socket, up to 32 GB for 2 sockets)
Storage Memory
M.2 SSD SATA x 1 (Disk 0)
2.5-inch SATA (HDD/SSD) x 1 (Disk 1)
SATA speed: 6 Gb/s, 3 Gb/s, 1.5 Gb/s
Graphic Accelerator
Intel UHD Graphics 620 (built in CPU)
Video Memory
Shared memory (UMA)
Maximum allocation size: Automatic allocation of up to half the installed main memory
Security chip
TPM 2.0
BIOS
UEFI BIOS
Watchdog timer
Timeout setting from either 1 to 255 seconds, or 1 to 255 minutes, is possible (set up using API)*1
Buzzer
Yes

1The watchdog timer is supported by products with the following system version.

Display specifications
Display Type
TFT Color LCD
Display Size
12.1" Wide
Resolution
1,280 x 800 pixels (WXGA)
Effective Display Area
W261.12 x H163.2 mm [W10.28 x H6.43 in.]
Display Colors
16 million colors
Backlight
White LED (not user replaceable. Please contact customer support.)
Backlight service life
50,000 hrs. or more (each in continuous operation at 25 °C [77 °F] before backlight brightness decreases to 50%)
Brightness Control
0 to 100 (Adjusted with touch panel or software)
Touch Panel Type
Projected capacitive with optimized noise filter
Touch points
Multi-touch (two-point touch)
Touchpanel lifetime
10 million times or more
Touch mode
Standard mode , water detection mode , glove mode
NOTE: For details, refer to Manual.
Electrical specifications
Rated Input Voltage
AC: 100 to 240 Vac
DC: 24 Vdc
Input Voltage Limits
AC: 85 to 264 Vac
DC: 18 to 31.2 Vdc
Allowable Voltage Drop
AC: 20 ms or less
DC: 5 ms or less
Power Consumption
AC
Max: 178 VA
When power is not supplied to external devices: 107 VA
When screen turns off (power is not supplied to external devices): 69VA
 
DC
Max: 156 W
When power is not supplied to external devices: 90 W
When screen turns off (power is not supplied to external devices): 58 W
In-Rush Current
30 A or less
Voltage Endurance
AC: 1,500 Vac for 1 minute (between power terminal and PE terminal)
DC: 1,000 Vac for 1 minute (between power terminal and FG terminal)
Insulation Resistance
AC: 500 Vdc, 10 MΩ or more (between power terminal and PE terminal)
DC: 500 Vdc, 10 MΩ or more (between power terminal and FG terminal)
Environmental specifications
International Safety Standards
CEUKCAcULuscULus Class 1 Division 2EACKCRCM
Surrounding Air Temperature
With HDD
Panel (Landscape) mounting: 0 to 40 °C (32 to 104 °F)
Panel (Portrait) mounting: 0...40 °C (32...104 °F)
 
Without HDD
Panel (Landscape) mounting: 0 to 55 °C (32 to 131 °F)
(for 19-inch Wide and 22-inch Wide: 0 to 50 °C (32 to 122 °F))
Panel (Portrait) mounting: 0 to 50 °C (32 to 122 °F)
*1
Storage Temperature
-20 to +60 °C [-4 to 140 °F]
Ambient Humidity
10% to 90% RH (Non condensing, wet bulb temperature 39 °C [102.2 °F] or less)
Dust
0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)
Pollution Degree
For use in Pollution Degree 2 environment
Corrosive Gases
Free of corrosive gases
Air pressure (altitude range)
800 to 1,114 hPa (2,000 m [6,561 ft.] or lower)
Vibration resistance
With HDD IEC 60068-2-6 compliant
5 to 9 Hz Single amplitude 1.75 mm (0.07 in)
9 to 150 Hz Fixed acceleration: 4.9 m/s2
X, Y, Z directions for 10 cycles (approximately 100 minutes)
 
NOTE: In an environment with vibrations, the read/write speed on the HDD may decrease.
 
Without HDD IEC/EN 61131-2 compliant
5 to 9 Hz Single amplitude 3.5 mm (0.14 in)
9 to 150 Hz Fixed acceleration: 9.8 m/s2
X, Y, Z directions for 10 cycles (approximately 100 minutes)
Concussion resistance
IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times
Noise Immunity
AC: Noise voltage 1,500 Vp-p
DC: Noise voltage 1,000 Vp-p
Pulse duration: 1 μs
Rise time: 1 ns
(via noise simulator)
Electrostatic Discharge Immunity
Contact Discharge Method: 6 kV
Air Discharge Method: 8 kV
(IEC/EN61000-4-2 Level 3)
Electromagnetic Compatibility (EMC)
IEC 61000-4-4
2 kV: Power port
1 kV: Signal ports

1The FAN kit is required when using this product with HDD installed.

Interface specifications
Serial (COM1)
Asynchronous transmission: RS-232C (not isolated) x 1
Data length: 7 or 8 bits
Stop bit: 1 or 2 bits
Parity: None, odd or even
Data transmission speed: 2,400 to 115,200 bps
Connector: D-Sub 9–pin (plug)
USB Type A
Connector:USB 3.0 (Type A) x 2, USB 2.0 (Type A) x 2
Power supply voltage: 5 Vdc ±5%
Maximum current supplied: USB 3.0 (Type A): 900 mA/port, USB 2.0 (Type A): 500 mA/port
Maximum transmission distance: USB 3.0 (Type A): 3 m (9.84 ft), USB 2.0 (Type A): 5 m (16.4 ft)
USB Type C
Connector: USB 3.0 (Type C) x 1
Power supply voltage: 5 Vdc ±5% or 12 Vdc ±5%, USB power delivery (source) supported
Maximum current supplied: 900 mA/port, 3000 mA/port when USB power delivery is enabled
Maximum transmission distance: 3 m (9.84 ft)
Resolution: Up to 4,096 x 2,304 pixels at 60 Hz
*1
Ethernet
Standard: IEEE1588, 10 BASE-T/ 100 BASE-TX/ 1000BASE-T, Wake-on-LAN (WOL) supported
Connector: Modular jack (RJ-45) x 2
*2
DisplayPort
Version: V 1.2, dual mode (DP++) supported
Resolution: Up to 4,096 x 2,304 pixels at 60 Hz

1The USB (Type C)interface supports alternate mode (DisplayPort) and USB power delivery (source, 5 Vdc/12 Vdc). When using USB power delivery, an E-Marked (electronically marked) cable is required.
When Advanced Box is connected to the Display Module, the power supply capability of USB power delivery is limited to 30 W.

2When the status is S4 (hybrid shutdown), Wake-on-LAN is unavailable.

Structural specifications
Grounding
AC Model: Protective grounding: Grounding resistance of 100 Ω or less, 2 mm2(AWG 14) or thicker wire, or your country's applicable standard
(SG and PE are connected inside the product.)
 
DC Model: Functional grounding: Grounding resistance of 100 Ω or less, 2 mm2(AWG 14) or thicker wire, or your country's applicable standard
(SG and FG are connected inside the product.)
Cooling method
Natural air circulation
Protective structure
IP66F, IP67F, UL 50/50E, Type 1, Type 4X (indoor use only), Type 12, Type 13
NOTE: On the front panel when properly installed in an enclosure.
External dimensions
W308.5 x H230.5 x D83 mm (W12.15 x H9.07 x D3.27 in)
Panel cut dimensions
W295 x H217 mm (W16.14 x H8.54 in)*1
Weight
5.1 kg (11.24 lb) or less

1For dimensional tolerance, everything +1/-0 mm (+0.04/-0 in) and R in angle are below R3 (R0.12 in).
Even if the installation wall thickness is within the recommended range for the Panel Cut Dimensions, depending on

Dimensions
External installation diagram

  1. Front
  2. Left
  3. Bottom

 

Panel cut dimensions
  1. 295 mm (+1/-0 mm) (11.61 in [+0.04/-0 in])
  2. 217 mm (+1/-0 mm) (8.54 in [+0.04/-0 in])
  3. 1.6...5 mm (0.06...0.2 in)

 

External dimensions with attached cable / Descriptions

Parts Identification and Functions

  1. Status LED