Title | Mitsubishi Electric Corporation Q/QnA Series Serial Communication Driver | ||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Version | Ver. 1.15.15 | ||||||||||||||||||||||||||||||||||||||||||||||||
Applicable Software | The required versions of software for this driver installer are as follows. GP-Pro EX Ver. 2.10.000 or later Pro-Server EX Ver. 1.30.000 or later You can check your version by "Help" function -> "Version Info". | ||||||||||||||||||||||||||||||||||||||||||||||||
Related Devices |
| ||||||||||||||||||||||||||||||||||||||||||||||||
Related Units | Required versions depend on models.
| ||||||||||||||||||||||||||||||||||||||||||||||||
Device/PLC Connection Manual | For details, please read the "Device/PLC Connection Manual" in the lower part of this page. For general information regarding Device connection and documentation conventions, please refer to "Device/PLC Connection Manual". | ||||||||||||||||||||||||||||||||||||||||||||||||
Updated Contents | [Ver. 1.15.15] (Dec. 22, 2023) The following issue was fixed:
|
How to install (This is a self-extracting file.)
-
! Prior to installation, be sure to close all software applications that are running.
-
- Click on the file name in the lower part of this page to start downloading the file.
- After download is complete, double-click on the downloaded file to start installation.
- Follow the instructions on the screen.
- After installation, start GP-Pro EX.
- Select [Mitsubishi Electric Corporation] for "Manufacturer" and [Q/QnA Series Ethernet] for "Series" in [Device/PLC] settings of [System Settings] on the [Project] menu.
When using the driver, be sure to refer to the Device Connection Manual PDF (Shown above). Also, for general information regarding Device connection and documentation conventions please refer to "Device/PLC Connection Manual".
Terms of use / Cautions
Please acknowledge the following terms of use before you use our download service.
Download of any file signifies your agreement to the terms of use.
Terms and conditions
Download file
Update History
[Ver. 1.15.15] (Dec. 22, 2023)
The following issue was fixed:
- GP3000, ST3000, LT3000, GP4000M series, part of GP4100 series (GP410x) failed to communicate with the controller when using "QnA Comp. 3C Frame: Format 4" in V1.15.14.
[Ver. 1.15.14] (Jan. 27, 2023)
The following functions are added:
- U\G / LCS / LCC / LCN are added to the support device.
- A switch of clear ON/OFF other bits of into same word is added when the bit access to the WORD devices.
[Ver. 1.15.12]
The following unit is supported:
- ST6000 Series
[Ver. 1.15.11]
The following issue was fixed:
- When select PC No.16 if using Q/QnA Link protocol, HMI sometimes can’t read from PLC/Device.
[Ver. 1.15.10]
The following function was added:
- When using the YOKODORI function, supports whole link unit initial command for Mitsubishi PLC link protocol
[Ver. 1.15.09]
The following issue was fixed:
- When using the YOKODORI function, a timeout error is displayed if set baud-rate 115200bps.
[Ver. 1.15.08]
The following issue was fixed:
- When converting from PROPB/III, project transmission sometime become fail.
[Ver. 1.15.07]
The following function was added:
- Support YOKODORI function (GP-4Gxx Only)
[Ver. 1.15.06] (Dec. 8, 2016)
The following issue was fixed:
- When using multiple CPUs, occasionally invalid values were read.
- Occasionally normal communication was not possible when using Serial Multi Link.
[Ver. 1.15.05] (Oct. 17, 2016)
The following settings were added:
- Multi CPU System is supported.
- Added Related Device Series.
MELSEC iQ-R Series, MELSEC iQ-F Series
[Ver. 1.14.05] (Dec. 12, 2014)
The following setting was added:
- Added Related Device.
Q03UDV CPU, Q04UDVCPU, Q06UDVCPU, Q13UDVCPU, Q26UDVCPU
The following issue was corrected:
- When GP430 series and GP4000 series are mixed in the serial multilink, all GPs cannot make communications.
[Ver. 1.14.04] (Jul. 7, 2014)
The following setting was added:
- LT3000 Series is supported.
[Ver. 1.13.04] (Mar. 29, 2010)
The following issue was corrected:
- Using the Serial Multilink function, the display may not pass the token to other displays when the screen is changed.
[Ver. 1.13.03] (Oct. 5, 2009)
The following issues were corrected:
- When not connecting via the Q Series C24 I/F Module, the ComErr lamp of the unit lights.
[Ver. 1.13.02] (Aug. 5, 2009)
The following settings were added:
- Supported QnA Comp. 3C Frame: Format 4"
- Supported Serial Multilink function
- Added Related Device
Q00UJCPU/Q00UCPU/Q01UCPU/Q10UDHCPU/Q20UDHCPU/Q03UDECPU/Q04UDEHCPU/
Q06UDEHCPU/Q10UDEHCPU/Q13UDEHCPU/Q20UDEHCP/UQ26UDEHCPU
[Ver. 1.12.02] (Aug. 24, 2007)
The following settings were added:
- Administration Bureau of MELSECNET and the master bureau of a remote IO net can be specified at the connection destination.
Summary
Last Update : 2023/12/22