Title | KEYENCE Corporation KV-700 - 8000 SIO Driver | ||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Version | Ver. 1.18.15 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Applicable Software | GP-Pro EX Ver2.10.000 or later Pro-Server EX Ver.1.30.000 or later You can check your version by”Help”function→”Version Info”. | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Related Devices |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||
Related Units | Required versions depend on models. Please check "Supported Models / Version" for the required versions of GP-Pro EX. Required driver versions for different models are listed below
| ||||||||||||||||||||||||||||||||||||||||||||||||||||
Device/PLC Connection Manual | For details, please read the "Device/PLC Connection Manual" in the lower part of this page. For general information regarding Device connection and documentation conventions please refer to "Device/PLC Connection Manual(link is external)". | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Updated Contents |
[Ver. 1.18.15] (Mar. 11, 2022) The following settings were added:
|
How to install (This is a self-extracting file.)
Please confirm that the supported software is installed in your computer. Prior to installing the driver, close all your personal computer applications, including any resident programs such as virus detection program, etc.
- Click on the above file name to download the data to desired folder.
- After the download to your PC is finished, double-click on the file’s icon to start the installer program.
- After the installer starts, follow the instructions given on each screen.
- After installation, execute GP-Pro EX.
- Click on the Device/PLC area’s [KEYENCE Corporation] selection and select [KV-700 - 8000 SIO].
Terms of use / Cautions
Please acknowledge the following terms of use before you use our download service.Download of any file signifies your agreement to the terms of use.
Terms and conditions
Download file
Update history
[Ver. 1.18.15] (Mar. 11, 2022)
The following settings were added:- The driver name is changed to " KV-700 - 8000 SIO".
[Ver. 1.17.15] (Jun. 09, 2021)
The following functionalities were added:- KV-8000 Series Support
[Ver. 1.16.08]
The following settings were added:- GP-4G01 was supported.
* To use a GP-4G01 Ver. 4.07.000 or later of GP-Pro EX are necessary.
[Ver. 1.16.06] (Nov. 27, 2015)
The following functionalities were added:- KV-7000 Series Support
- KV-Nano Series Support
[Ver. 1.15.06] (Jul. 27, 2012)
The following functionalities were added:- LT3000 Support
- USB-Serial (RS-422/485) Conversion Adapter Support
[Ver. 1.14.06] (Feb. 17, 2012)
The following issues were corrected:- If "38400" or more is specified in the pass-through function, communication may not be made normally.
- When the pass-through function is used via Ethernet, connection to PLC cannot be made.
[Ver. 1.14.05]
The following issue was corrected:- A device comment cannot be transferred via the pass-through function.
[Ver. 1.14.04]
The following setting was added:- GP4000 Series were supported.
* GP-Pro EX Ver. 3.00.000 or later is necessary to use GP4000 Series.
- When the program development tool is left online for long hours in the use of pass-through function, the communication error may occur.
[Ver. 1.14.03]
The following settings were added:- GP4000M Series were supported.
* GP-Pro EX Ver. 2.71.000 or later is necessary to use GP4000M Series.
- GP-4104 was supported.
* GP-Pro EX Ver. 2.70.000 or later is necessary to use GP-4104 (Ethernet Multilink).
- Reading 126 or more inconsecutive addresses of ZF device may cause a communication error.
[Ver. 1.14.02]
The following setting was added:- GP-4105 and GP-4106 were supported.
* GP-Pro EX Ver. 2.60.000 or later is necessary to use GP-4105 or GP-4106.
[Ver. 1.13.02] (Oct. 16, 2008)
The following setting was added:- Support for Pass-through.
[Ver. 1.12.02] (Aug. 21, 2008)
The following issue was corrected:- When the KV-700/1000 series is selected, the address of an Input Relay / Output Relay / Internal Auxiliary Relay cannot be correctly set.
[Ver. 1.12.01] (Mar. 17, 2008)
The following settings were added:- KV-3000Series/KV-5000 Series are supported.
- The driver name is changed to "KV-700/1000/3000/5000 CPU Direct".
[Ver. 1.11.01] (Oct. 31, 2007)
The The following setting was added:- Support for Device Monitor
* GP-Pro EX Ver. 2.00.000 or later is necessary to use a Device Monitor.