Details
- Note:
- Precautions for adding a new driver onto Windows Vista/7
Precautions for adding a new driver at Daylight Saving Time
Title | Mitsubishi Electric Corporation Q/QnA Series Ethernet Driver | |||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Version | Ver. 1.17.13 | |||||||||||||||||||||||||||||||||||
Applicable Software | The required versions of software for this driver installer are as follows. GP-Pro EX Ver. 2.10.000 or later Pro-Server EX Ver. 1.30.000 or later You can check your version by "Help" function -> "Version Info". | |||||||||||||||||||||||||||||||||||
Related Devices |
| |||||||||||||||||||||||||||||||||||
Related Units | Required versions depend on models. Please check "Supported Models / Version" for the required versions of GP-Pro EX. Required driver versions for different models are listed below.
| |||||||||||||||||||||||||||||||||||
Device/PLC Connection Manual | For details, please read the "Device/PLC Connection Manual" in the lower part of this page. For general information regarding Device connection and documentation conventions, please refer to "Device/PLC Connection Manual". | |||||||||||||||||||||||||||||||||||
Updated Contents |
[Ver. 1.17.13] (Jan. 27, 2023) The following functions are added:
|
How to install (This is a self-extracting file.)
- ! Prior to installation, be sure to close all software applications that are running.
-
- Click on the file name in the lower part of this page to start downloading the file.
- After download is complete, double-click on the downloaded file to start installation.
- Follow the instructions on the screen.
- After installation, start GP-Pro EX.
- Select [Mitsubishi Electric Corporation] for "Manufacturer" and [Q/QnA Series Ethernet] for "Series" in [Device/PLC] settings of [System Settings] on the [Project] menu.
Terms of use / Cautions
Please acknowledge the following terms of use before you use our download service.Download of any file signifies your agreement to the terms of use.
Terms and conditions
Download file
Update History
[Ver. 1.17.13] (Jan. 27, 2023)
The following functions are added:- U\G / LCS / LCC / LCN are added to the support device.
- Network communication is supported if select iQ-F series.
- A switch of clear ON/OFF other bits of into same word is added when the bit access to the WORD devices.
[Ver. 1.16.11]
The following issue is fixed:- HMI sometime couldn't boot when doesn't connect target device, after update of the "time update setting".
[Ver. 1.16.10]
The following issue is fixed:- HMI sometime became communication error when TCP/IP connect with iQ-F, if format is selected ASCII mode.
[Ver. 1.16.09] (Feb. 19, 2021)
The following unit is supported:- ST6000 Series
[Ver. 1.16.07] (Mar. 13, 2017)
The following issue is fixed:- Cannot install Ver. 1.16.07 installer (Oct, 2016 version) at twice.
[Ver. 1.16.07] (Oct. 17, 2016)
The following settings were added:- iQ-R Series
- iQ-F Series
[Ver. 1.15.07] (Dec. 12, 2014)
The following setting was added:- High-Speed Universal Model (QnUDVCPU) is supported.
- Communication with an external device may be stopped temporarily and restarted.
[Ver. 1.14.06] (Jul. 7, 2014)
The following setting was added:- LT3000 Series is supported.
[Ver. 1.12.05] (Apr. 30, 2008)
The following issues were corrected:- When connecting it with CPU unit of Q series high performance model function version A, it becomes a communication fault.
- The ComErr lamp of the Ethernet unit lights.
[Ver. 1.12.04] (Sep. 28, 2007)
The following settings were added:- Multi CPU System is supported.
- Support for Ladder Monitor. *Ver. 2.00.000 or later version of GP-Pro EX and "Mitsubishi Electric Q Series PLC Ladder Monitor" are necessary to use a Ladder Monitor.
[Ver. 1.11.04] (Jan. 15, 2007)
The following setting was added:- Support for Device Monitor. *Ver. 2.00.000 or later version of GP-Pro EX are necessary to use a Device Monitor.
[Ver. 1.10.04] (Jul. 31, 2006)
The following issue was corrected:- The error occurs when "File Register(ZR)" is read.
Summary
Last Update : 2023/01/27