Please note that the end date of sales may be subject to change, and due to the limited availability of the products in stock, shipping will end when the stock is over. We appreciate your understanding.
The latest information is here Discontinued Product and Substitution
Serial Interface
* For host controllers and connection cables, refer to the corresponding device driver manual of your screen editing software.Product Name | Model No. | Description | Supported Model |
---|---|---|---|
9-pin-to-25-pin RS-232C Conversion Cable (0.2 m) | CA3-CBLCBT232-01 | Cable for converting a D-Sub 9-pin plug to a D-Sub 25-pin socket (RS-232C). | Box Module |
RS-422 9/25-pin Conversion Cable (0.2 m) | PFXZCBCBCVR41 | Cable for converting a D-Sub 9-pin plug to a D-Sub 25-pin socket (RS-422). | |
COM Port Conversion Adapter | CA3-ADPCOM-01 | Connects optional RS-422 communication items to Serial Interface. | |
RS-422 Terminal Block Conversion Adapter | PFXZCBADTM1 | Connects output from a Serial Interface (D-sub 9 pin plug) directly to an RS-422 terminal block. | |
RS-232C Isolation Unit | CA3-ISO232-01 | Connects a host controller to this product and provides isolation. (RS-232C and RS-422 are switchable). |
USB (Type A)
Product Name | Model No. | Description | Supported Model |
---|---|---|---|
USB Cable (5 m) | FP-US00 | Connects a USB printer (TYPE-B). | Box Module |
USB Front Cable (1 m) | CA5-USBEXT-01 | Extension cable attaching USB interface to front panel. | |
USB-Serial (RS-232C) Conversion Cable (0.5 m) | CA6-USB232-01 | Cable for converting a USB interface into a serial interface (RS-232C). Allows connection to modems *1 or bar code readers *2 that support RS-232C. | |
USB/RS-422/485 Conversion Adapter | PFXZCBCBCVUSR41 | Adapter for connecting this product (USB Type A) to an external device (RS-422/RS-485). | |
EZ Tower Light tube mounting fixing plate | PFXZCETWHA1 | USB Connection Type Monolithic EZ Tower Light tube mounting with fixing plate. | |
EZ Tower Light with base mounting | PFXZCETWW1 | USB Connection Type Monolithic EZ Tower with base mounting. | |
EZ Illuminated Switch | PFXZCCEUSG1 | A unit of 5 illuminated switches with multiple color LED connected to this product via USB. | |
EZ Fingerprint Recognition Unit | PFXZCCEUSS1 | Fingerprint recognition unit connected to this product via USB. | |
EZ Numpad | PFXZCCEUKB1 | Numpad connected to this product via USB. |
USB (mini B)
Product Name | Model No. | Description | Supported Model |
---|---|---|---|
USB Transfer Cable (USB Type A / mini-B) (1.8 m) *3 | ZC9USCBMB1 | Cable for transferring screen data from a PC (USB Type A) to this product (USB mini-B). | Box Module |
USB Panelmount Extension Cable (USB mini-B) (1 m) | ZC9USEXMB1 | Extension cable that attaches to the USB (mini-B) interface on the front side of the operation panel. | |
USB Clamp mini-B (1 port) | ZC9USCLMB1 | Clamp to prevent disconnection of USB cable (USB/mini-B, 1 port, 5 clamps/set). |
Software
Product Name | Model No. | Description |
---|---|---|
GP-Pro EX Software Licenses and Related Software | See Product webpage for the details. | HMI Screen editor & Logic Programming Software and Related Software |
Pro-face Connect | See Product webpage for the details. | "Pro-face Connect" is a ready-to-use solution for Secure Remote Access Over the Internet |
Others
Product Name | Model No. | Description | Supported Model | |
---|---|---|---|---|
7.0-inch Wide Box Module Fixing Bracket | PFXZCHBMFBS1 | For SP5000X Series, Bracket for fixing Box module to Display module (1 piece) | SP-5490WA | |
12.1-inch Wide & 15.6-inch Wide Box Module Fixing Bracket | PFXZCHBMFBL1 | For SP5000X Series, Bracket for fixing Box module to Display module (1 piece) | SP-5690WA SP-5790WA | |
DC Power Supply Connector with fixable screws | CA7-ACCNL-01 | Connector to connect DC power supply cables (5 pcs/set) | Display Module (except 7-inch Wide Display Module) | |
Auxiliary Output / Speaker Output Interface | AUX Connector | PFXZCDCNAUX1 | AUX connector required in case an external output is used (5 pcs/set). | Box Module |
Storage *4 | SD Memory Card (4GB) | PFXZCBSD4GC41 | SD Memory Card (4GB, MLC, CLASS4) | |
Replacement Battery *5 | PFXZCBBT1 | Primary battery for time data backup (1 piece) |
Maintenance
Product Name | Model No. | Description | Supported Model |
---|---|---|---|
7-inch Wide Installation Gasket | PFXZCDWG72 | Provides dust and moisture resistance when GP is installed into a solid panel (1 piece) | 7-inch Wide Display Module |
12-inch Wide Installation Gasket | PFXZCDWG122 | 12-inch Wide Display Module | |
15-inch Wide Installation Gasket | PFXZCHWG154 | 15-inch Wide Display Module | |
DC Power Supply Connector (Straight type) | PFXZCBCNDC1 | Connector to connect DC power supply cables (Straight type, 5pcs/set) | SP-5490WA |
DC Power Supply Connector with fixable screws (Angle type) | PFXZCHCNDC3 | Connector with fixable screws to connect DC power supply cables (Angle type, 5pcs/set) | SP-5690WA SP-5790WA |
USB Clamp Type A (1 port) | PFXZCBCLUSA1 | Clamp to prevent disconnection of USB cable (USB/A, 1 port, 5 clamps/set) | Box Module |
SD Memory Card (1 GB) | PFXZCDSD1GC61 | SD Memory Card (1 GB, SLC, Class 6) for System Card | |
Fieldbus Unit Fixing Bracket | PFXZCHFUFB1 | For SP5000X Series/SP5000X Series, Bracket for fixing Fieldbus unit to Box module (1 piece) |
Expansion Unit
Product Name | Model No. | Description | Supported Model |
---|---|---|---|
PROFIBUS DP Slave/MPI Unit *6 | PFXZCDEUPF1 | Expansion unit that enables participation of the SP5000 Series, in the PROFIBUS network and communication with the PROFIBUS DP master. | Box Module |
J1939 Unit | PFXZCHEUJ1 | Expansion unit that enables participation in the J1939 communication network. | |
CANopen Master Unit | PFXZCHEUCAM1 | Expansion master unit to connect CANopen slave unit (bit input/output 1024 points / integer input/output 256 points) | |
CANopen Slave HTB Unit | HTB1C0DM9LP | Slave unit supporting CANopen with 12 digital inputs, 6 relay outputs and 2 transistor source outputs. Up to 7 units of EX modules can be connected. | CANopen Master Unit |
DIO Connector for HTB * Maintenance Item | CA7-HTBCNSET-01 | DIO Connector for HTB (13-pin connector for input and 16-pin connector for output, 1 pc each/set) | |
8-point Input Module | EXM-DDI8DT | 8-point sink-source shared type expansion unit | |
16-point Input Module | EXM-DDI16DT | 16-point sink-source shared type expansion unit | |
8-point relay output module | EXM-DRA8RT | 8-point relay output (2 common) type expansion unit | |
16-point relay output module | EXM-DRA16RT | 16-point relay output (2 common) type expansion unit | |
8-point transistor output module | EXM-DDO8UT | 8-point transistor output sink type expansion unit | |
16-point transistor output module | EXM-DDO16UK | 16-point transistor output sink type expansion unit | |
8-point transistor output module | EXM-DDO8TT | 8-point transistor output source type expansion unit | |
16-point transistor output module | EXM-DDO16TK | 16-point transistor output source type expansion unit | |
4-Point Input/ 4-Point Output Module | EXM-DMM8DRT | 4-point input sink-source and 4-point relay output type expansion unit (1 common) mixed I/O unit | |
16-Point Inputs/ 8-point Relay Output Module | EXM-DMM24DRF | 16-point input sink-source / 8-point relay output mixed I/O type expansion unit | |
2-ch Analog Input Module | EXM-AMI2HT | 2-ch analog input type expansion unit | |
2-ch Thermocouple Pt100 Input/ 1-ch Analog Output Module | EXM-ALM3LT | 2-ch analog input / 1-ch analog output type expansion unit | |
2-ch Analog Input/ 1-ch Analog Output Module | EXM-AMM3HT | 2-ch analog input / 1-ch analog output type expansion unit | |
1-ch Analog Output Module | EXM-AMO1HT | 1-ch analog output type expansion unit | |
4-ch Voltage, Current, Pt100/ Pt1000/Ni100/Ni1000 Input Module | EXM-AMI4LT | 4-ch Voltage, Current, Temperature Expansion Unit | |
2-ch Analog Output Module | EXM-AVO2HT | 2-ch analog output type expansion unit | |
4-ch Analog Input/ 2-ch Analog Output Module | EXM-AMM6HT | 4-ch analog input / 2-ch analog output expansion unit | |
8-ch Temperature Pt100/ Pt1000 Input Module | EXM-ARI8LT | 8-ch temperature input type expansion unit | |
MIL Connector (20 pin) for EX module * Maintenance Item | CA6-EXMCNHE20P-01 | Connector for EX Module (5 pcs/set) | |
FLEX NETWORK Master Unit *7 | PFXZCHEUFN1 | FLEX NETWORK Master Unit for SP5000 Series | Box Module |
32-point input Sink/Source and 32-point transistor output Sink type | FN-XY32SKS41 | Input/output combination I/O unit of 32-point input sink/source and 32-point transistor output Sink type | FLEX NETWORK Master Unit |
32-point input Sink / Source type | FN-X32TS41 | I/O unit of 32-point input sink/source sharing type | |
16-point input Sink/Source and 16-point transistor output Sink type | FN-XY16SK41 | Input/output combination I/O unit of 16-point input sink/source and 16-point transistor output Sink type | |
16-point input Sink/Source and 16-point transistor output Source type | FN-XY16SC41 | Input/output combination I/O unit of 16-point input sink/source and 16-point transistor output Source type | |
2-channel Analog / Digital Conversion Unit | FN-AD02AH41 | Converts 2-channel analog signals to digital signals | |
2-channel Digital/Analog Conversion Unit | FN-DA02AH41 | Converts 2-channel 12-bit digital signals to analog signals and outputs the result | |
Communication Cable (50m) | FN-CABLE2050-31-MS | Cables for connecting FLEX NETWORK master unit and FLEX NETWORK units | |
Communication Cable(200m) | FN-CABLE2200-31-MS | ||
FLEX NETWORK Connector * Maintenance Item | PFXZCHCNFN2 | Connector to attach FLEX NETWORK master unit (5 pcs/set) | |
64-point DIO Connector * Maintenance Item | GLC-DIOCN03 | FN-XY32SK41 Connectors (2 pcs/set) |
*1 For supported models, refer to the Pro-face's support site.
*2 Make sure your screen editing software supports the product.
*3 You can connect using just one of the available USB interfaces.
*4 You can also use a commercial type.
*5 SP5000X Series can save NVRAM (Backup memory) and RTC (Time) without battery. But when you need to keep RTC (Time) more than 100 days without turning on electricity,you need to add the option.
*6 MPI (12MB) Communication will be supported at a later date.
*7 Also R7 Series of M-System Co., Ltd. (FLEX NETWORK remote I/O) can be connected.